Pelco cs73m-d operation manual Connecting the MDA to AN External PC

Page 13

NOTE: The CM9760-MDA is configured at the factory for RS-422 communication. To communicate via RS-232, an internal DIP switch must be changed. Refer to the Communication Ports Setup section.

NOTE: The pin numbering of the wall block shown in Figure 5 applies to the Pelco RJ-45 wall block. A wall block purchased from a supplier other than Pelco may have a different pin numbering scheme.

CONNECTING THE MDA TO AN EXTERNAL PC

Perform this step if you are going to program your CM9760-MDA unit using a PC (personal computer).

Refer to Figure 5 and make a cable to connect the MDA to the PC. The figure shows a typical nine-pin sub ÒDÓ connector for the PCÕs COM 1/COM 2 serial port. Computers may differ regarding connector types and pin-outs. Therefore, always refer to the computerÕs manual to determine proper pin-outs.

If more than one MDA is to be programmed using a PC, note the following:

¥A maximum of 16 MDA units can be daisy-chained. To daisy-chain up to 16 MDA units, connect the RS-422 output of the first MDA unit to the RS-422 input of the second MDA unit and continue this method until the last MDA unit is connected (refer to Table D and to Figure 39).

¥If more than 16 MDAs are to be connected to a PC, a CM9760-CDU-T must be used. Refer to Figure 40 for an example of connecting over 16 MDAs to a PC. Note that a maximum of 64 MDA units can be connected to a PC for programming.

Table D. MDA RJ-45 Connector Pin-Outs

Pin Out

RS-232 Function

RS-422 Function

RS-485 Function

 

 

 

 

1

Transmit

Transmit +

Transmit +

2

No Connection

Transmit -

Transmit -

3

No Connection

No Connection

No Connection

4

Ground

Ground

Ground

5

Ground

Ground

Ground

6

No Connection

No Connection

No Connection

7

No Connection

Receive -

Receive -

8

Receive

Receive +

Receive +

 

 

 

 

 

 

 

 

 

 

MDA SIDE

 

 

 

 

 

 

 

 

 

 

CM9760-MDA

 

 

 

 

 

 

14

15

16

 

 

PIN 8

PIN 1

 

 

 

 

 

 

PGM

 

120V A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MON

 

 

 

 

 

 

PC SIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

COM1

COM2

 

COM1 RJ-45

 

 

 

 

 

 

 

UNI T

 

 

CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REVERSED CABLE

 

RJ-45

 

 

COMPUTER

 

 

 

COMPUTER

 

 

 

 

 

 

 

 

 

 

 

CONNECTOR

 

 

TRANSMIT

 

 

 

RECEIVE

 

 

 

 

 

 

 

 

 

 

 

 

REVERSED CABLE CONNECTIONS

 

 

 

 

 

 

 

 

 

5

4

3

2

1

 

8

 

1

WALL BLOCK

CM9760-MDA

 

 

 

 

RJ-45

RJ-45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

2

CONNECTOR

CONNECTOR

 

 

 

 

 

 

 

 

 

9

 

8

7

6

 

 

 

 

PIN 1=TX

PIN 1=TX

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

3

 

 

 

 

 

 

 

 

5

 

4

PIN 8=RX

PIN 8=RX

 

 

 

GROUND

 

 

WALL BLOCK

 

 

Figure 5. PC Connection to CM9760-MDA

12

Pelco Manual C573M-D (11/03)

Image 13
Contents Important Notice System Contents List of Tables List of IllustrationsMaster MDA Time and Date Generator for 63 MDA Slave Units CM9760-CC1 Connection to over 16 MDA UnitsDescription Important Safeguards and WarningsOverview System Configuration Rear Panel View Mounting Hardware SetupModels CommunicationSwitch Settings Port Setup Selected Communication Ports SetupSwitch Settings Camera Range Selected Address Setup for Daisy ChainingCameras Resetting to Factory Defaults Setting UP a Unit AS the Master ClockVideo Connections Clearing TITLE/TIME/DATE Text Display on ALL ChannelsCable Type Maximum Distance Data Connections Connecting the MDA to a System 9740/9760 ControllerPin Out RS-232 Function RS-422 Function RS-485 Function Connecting the MDA to AN External PCTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to a KBD200A or KBD300A Keyboard Connecting the MDA to a CM9760-KBD KeyboardPower Connections Keyboard WiringProgramming Time and Date SetupProgramming Methods Programming with a KeyboardÒhost Direct CAM CTRL.Ó Entering the Programming Mode with the CM9760-KBDSET Camera Title Main MenuSET Camera Display SET Cable CompensationEnable Video Enable TimePosition DisplayDEC-31-02 SET Time and Date115952 PM Table E. CM9760-CC1/CM9760-MDA Format MatchupProtocol SET PortBaud Rate Data BitsSystem Requirements Reset MDAStop Bits ParityInstalling the CM9760-MDA Setup Program Login Dialog Box Starting the CM9760-MDA Setup ProgramSET Password CM9760-MDA Setup Dialog BOXSET System SET Unit IDEnter the Unit ID number 1-64, and then click OK System Communication Setup Dialog Box Set Time and Date Dialog Box CM9760-CC1 CM9760-MDA SET TitlesPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box Message Text Editing Dialog Box SET Message TextCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Video Alphanumeric Overlays Send DataSymptom Possible Problem Possible Solution TroubleshootingSpecifications Ratings GeneralAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-422 RS-232 CM9760-MDACM9760-CDU-T PV130CM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers = Data Non-Coaxitron System SetupCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Asterisk Appendix B Supported Title and Message Text CharactersCommand Function Command Format Appendix C Message Text Insertion CommandsPelco Manual C573M-D 11/03 Radio and Television Interference Regulatory NoticesRevision History Warranty and Return Information