Pelco cs73m-d operation manual Sample Command Data Window

Page 39

The following sections provide additional information about functions that can be performed from the Message Text Editing dialog box.

Showing Commands: You can display command transactions between the PC and the MDA by selecting the Show Commands checkbox in the Message Text Editing dialog box. The Command Data window displays the command sent to the MDA and the response sent from the MDA each time you click a command button in the Message Text Editing dialog box. The command transaction is displayed in hexadecimal format and in ASCII format.

Figure 34 provides a sample of a Command Data window. The message Hello World was sent from the PC to the MDA using the Send Row 1 command button.

Figure 34. Sample Command Data Window

Note the following:

¥The ASCII equivalent of hexadecimal data 00 to 1F and hexadecimal data 80 and beyond is represented as dots.

¥When the MDA acknowledges the command that was sent to it, the MDA responds by sending A2 as shown in Figure 34. If the MDA does not acknowledge the command that was sent to it, the MDA responds by sending AA.

For additional information about message text commands, refer to Appendix C in this manual.

Scrolling Message Text: If you have set message text on a selected unit and channel for a specified number of rows, the MDA allows you to scroll message text to allow a new message to be displayed.

To scroll message text, do the following:

1.In the Rows to Display formatting list box, specify the number of text rows that can be scrolled and displayed.

2.Send the formatting to the selected unit and channel(s) by clicking the Send Current Formatting button.

3.In the Scroll Text entry box, enter the desired message text and then click the Scroll Text button.

Message text scrolls as follows. Each row that is scrolled moves upward one row. As a result, the first row of message text is overwritten. The new message is displayed in the bottom row, which is determined by the number of rows specified in the Rows to Display formatting setting.

38

 

Pelco Manual C573M-D (11/03)

 

 

 

Image 39
Contents Important Notice System Contents CM9760-CC1 Connection to over 16 MDA Units List of IllustrationsList of Tables Master MDA Time and Date Generator for 63 MDA Slave UnitsImportant Safeguards and Warnings DescriptionOverview System Configuration Rear Panel View Communication Hardware SetupMounting ModelsSwitch Settings Port Setup Selected Communication Ports SetupAddress Setup for Daisy Chaining Switch Settings Camera Range SelectedCameras Resetting to Factory Defaults Setting UP a Unit AS the Master ClockClearing TITLE/TIME/DATE Text Display on ALL Channels Video ConnectionsCable Type Maximum Distance Data Connections Connecting the MDA to a System 9740/9760 ControllerConnecting the MDA to AN External PC Pin Out RS-232 Function RS-422 Function RS-485 FunctionTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to a KBD200A or KBD300A Keyboard Connecting the MDA to a CM9760-KBD KeyboardPower Connections Keyboard WiringProgramming with a Keyboard Time and Date SetupProgramming Programming MethodsÒhost Direct CAM CTRL.Ó Entering the Programming Mode with the CM9760-KBDSET Camera Title Main MenuSET Camera Display SET Cable CompensationDisplay Enable TimeEnable Video PositionTable E. CM9760-CC1/CM9760-MDA Format Matchup SET Time and DateDEC-31-02 115952 PMData Bits SET PortProtocol Baud RateParity Reset MDASystem Requirements Stop BitsInstalling the CM9760-MDA Setup Program Login Dialog Box Starting the CM9760-MDA Setup ProgramSET Password CM9760-MDA Setup Dialog BOXSET Unit ID SET SystemEnter the Unit ID number 1-64, and then click OK System Communication Setup Dialog Box Set Time and Date Dialog Box CM9760-CC1 CM9760-MDA SET TitlesPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box Message Text Editing Dialog Box SET Message Text Command Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Video Alphanumeric Overlays Send DataSymptom Possible Problem Possible Solution TroubleshootingSpecifications Ratings GeneralAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-422 RS-232 CM9760-MDACM9760-CDU-T PV130CM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers = Data Non-Coaxitron System SetupCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Asterisk Appendix B Supported Title and Message Text CharactersCommand Function Command Format Appendix C Message Text Insertion CommandsPelco Manual C573M-D 11/03 Radio and Television Interference Regulatory NoticesRevision History Warranty and Return Information