Pelco cs73m-d operation manual Main Menu, SET Camera Title

Page 18

NOTE: If you are using a KBD200A keyboard, use the appropriate pan/tilt key (up, down, right, left) in place of moving the joystick.

MAIN MENU

PELCO MDA UNIT 01

SOFTWARE VERSION 2.05

MAIN MENU:

1.

CAMERA TITLE

2.

COMPENSATION

3.

CAMERA DISPLAY

4.

TIME/DATE

5.

PORTS

6.

RESET

7.

EXIT

 

Figure 9. Main Menu

The fields in the Main Menu (Figure 9) are defined as follows:

PELCO

The first line is the title line. It contains the Unit ID as set from the MDA

MDA UNIT

unitÕs rear panel.

SOFTWARE

This field shows the version of software being used.

VERSION

 

MAIN MENU

This field instructs you to pick an item to set from the six selections

 

listed or to exit the setup program.

A number precedes each of the seven selections. It flashes when the cursor is positioned on it. To select an item, move the keyboardÕs joystick up or down to position the cursor on the item you desire, then press the joystick to the right.

Selecting items 1 through 6 will display another menu. When you finish programming, select EXIT and press the joystick right, or exit by pressing the NEAR key.

SET CAMERA TITLE

If you choose item 1 on the Main Menu, the program displays the following menu:

CAMERA 01

CAMERA TITLE:

LOADING DOCK 4

RETURN

Figure 10. Set Camera Title Menu

Use this menu to enter a camera title. When the program displays this menu, the camera number flashes on the menuÕs top line.

¥If you want to edit the information for the camera number displayed, press the OPEN key.

¥If you want a different camera, press the joystick to the right to bring up the next camera. The title already programmed for the selected camera is displayed.

Use the joystick to access the title. Move the joystick left and right to position the cursor over a character in the title. Use the OPEN/CLOSE key to access a character. Pressing the joystick right places the cursor on the next character to program.

When you finish programming the title, press the joystick down to move the cursor to RETURN on the menu and then press the joystick to the right. This returns you to the Main Menu.

Pelco Manual C573M-D (11/03)

17

Image 18
Contents Important Notice System Contents Master MDA Time and Date Generator for 63 MDA Slave Units List of IllustrationsList of Tables CM9760-CC1 Connection to over 16 MDA UnitsImportant Safeguards and Warnings DescriptionOverview System Configuration Rear Panel View Models Hardware SetupMounting CommunicationCommunication Ports Setup Switch Settings Port Setup SelectedAddress Setup for Daisy Chaining Switch Settings Camera Range SelectedCameras Setting UP a Unit AS the Master Clock Resetting to Factory DefaultsClearing TITLE/TIME/DATE Text Display on ALL Channels Video ConnectionsCable Type Maximum Distance Connecting the MDA to a System 9740/9760 Controller Data ConnectionsConnecting the MDA to AN External PC Pin Out RS-232 Function RS-422 Function RS-485 FunctionTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to a CM9760-KBD Keyboard Connecting the MDA to a KBD200A or KBD300A Keyboard Keyboard Wiring Power ConnectionsProgramming Methods Time and Date SetupProgramming Programming with a KeyboardEntering the Programming Mode with the CM9760-KBD Òhost Direct CAM CTRL.ÓMain Menu SET Camera TitleSET Cable Compensation SET Camera DisplayPosition Enable TimeEnable Video Display115952 PM SET Time and DateDEC-31-02 Table E. CM9760-CC1/CM9760-MDA Format MatchupBaud Rate SET PortProtocol Data BitsStop Bits Reset MDASystem Requirements ParityInstalling the CM9760-MDA Setup Program Starting the CM9760-MDA Setup Program Login Dialog BoxCM9760-MDA Setup Dialog BOX SET PasswordSET Unit ID SET SystemEnter the Unit ID number 1-64, and then click OK System Communication Setup Dialog Box Set Time and Date Dialog Box SET Titles CM9760-CC1 CM9760-MDAPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box SET Message Text Message Text Editing Dialog BoxCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Send Data Video Alphanumeric OverlaysTroubleshooting Symptom Possible Problem Possible SolutionSpecifications General RatingsAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-232 CM9760-MDA RS-422PV130 CM9760-CDU-TCM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers Non-Coaxitron System Setup = DataCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Appendix B Supported Title and Message Text Characters AsteriskAppendix C Message Text Insertion Commands Command Function Command FormatPelco Manual C573M-D 11/03 Regulatory Notices Radio and Television InterferenceWarranty and Return Information Revision History