Alliance Laundry Systems CI 2050/325, CI 1650/325 instruction manual

Page 19

3

Equivalent pipe length in m for selected single resistances :

Right-angled corner : 13.4

90 degrees smooth bend R/D = 2 : 2.1

90 degrees angular bend R/D = 2 (three sections) : 2.6

90 degrees angular bend R/D = 2 (five sections) : 2.1

In general, we recommend that the pressure loss in the exhaust pipe is kept as low as possible.

If more machines are to be connected to the same exhaust channel, it is necessary to contact a ventilating firm that can advise you with regard to the correct dimensioning of the exhaust channel.

The pressure loss in the exhaust channel can be calculated in the following way :

Pchannel = Pd + Iength channel x ∆p

If Pchannel > 300 Pa, we recommend to increase the pipe dimension.

For this purpose, a prefabricated transfer piece is to be used.

To avoid noise, we advise to keep the maximum velocity in the pipe under 12 m/sec.

19

Image 19
Contents September Part No. D1273Page Contents Explanation of Safety Messages Safety InformationPage Safety notice Important Safety Instructions Page Intended use Product descriptionDescription of structural components Workplaces and noise level 1650/325 2050/325 Technical data CI1650/325, CI2050/325Sound level measurement Warranty and service instructions Transport and machine fastening Initial setup of the machine30 cm Setting up the machinePage Page Page 16A Page Ventilation of the room Basic checksExhaust gases Air filtersOperating devices and their position OperationStarting the machine Pedal Set the iron temperatureFunctions Set the ironing speedEnding Return button not with guiding ribbonsFailure and information signals Page Page Page Feeding sheets and towels Machine function, adjustment and troubleshootingDescription of machine functions General description of machine functionOperating the foot pedal option Advice Setting the temperatureSetting the speed Manual drive Guiding ironing belts Adjustments of the machineTightening the drive chain Tightening the ironing belts Tightening the feeding belts Adjusting the gap between input table and main roll Fault Cause Remedy TroubleshootingFault Condition Possible cause Fault Condition Solution After resetElectric heating control Temperature controlDescription of the control system General description of the control systemSpeed control Control of exhaust ventilatorStart/stop function Control panel and function keys Manual version Menu structure and how to enterMenu structure Manu adjusting menu Coin adjusting menu C2L coin 2 low Add XX defaultC1M coin 1 Medium C1H coin 1 HighTechnical menu Start PWM default Kp Xxxx default gas 300 default elecKd Xxxx default gas 1000 default elec Ki Xxxx default gas 0.5 default elecTMP REv Y/n default YES not adjustable with coinDiSP Display menuCentral panel Sigma explorerDaily maintenance MaintenanceSafety advice Maintenance schemeMonthly maintenance Weekly maintenancePage Page Half-yearly maintenance Feeding belts Drive Ironer beltsScrapers