Alliance Laundry Systems CI 2050/325, CI 1650/325 After reset, Fault Condition Solution

Page 43

5

Fault

Condition

Solution

OVL.d

I x t overload (I = current, t = time).

Reduce motor current (Load).

hot

Heatsink/IGBT temperature high.

Reduce ambient temperature or reduce motor current.

br.rS

Braking resistor overload.

Call Customer Service.

AC.Lt

Drive is in current limit.

Call Customer Service.

Burner

Fault

Cause

Remedy

Continuous

No supply voltage so also no burning

Check fuses and wiring.

malfunction

reset lamp.

 

after reset

Overheat.

Check overheat thermostat (see Fig. 1).

 

Short-circuit electrode to earth.

Adjust electrode properly -> ignition probe: 3 mm from burner

 

 

(see Fig. 2).

 

No gas supply.

Check gas supply, gas tap and function of the gas valves.

Malfunction

 

Adjust electrode properly.

burner after

No ignition spark.

2 start

 

Machine has no contact with earth.

 

Check electrical connection of the machine.

attempts

 

 

Check overheat thermostat.

 

 

 

No ignition while there is a spark.

No gas supply.

 

 

Wrong adjustment gas valve.

 

 

No PWM signal on ventilator (turns full at spark).

thermostat

3 mm

Fig. 1

Fig. 2

43

Image 43
Contents September Part No. D1273Page Contents Explanation of Safety Messages Safety InformationPage Safety notice Important Safety Instructions Page Intended use Product descriptionDescription of structural components Workplaces and noise level 1650/325 2050/325 Technical data CI1650/325, CI2050/325Sound level measurement Warranty and service instructions Transport and machine fastening Initial setup of the machine30 cm Setting up the machinePage Page Page 16A Page Ventilation of the room Basic checksExhaust gases Air filtersOperating devices and their position OperationStarting the machine Pedal Set the iron temperatureFunctions Set the ironing speedEnding Return button not with guiding ribbonsFailure and information signals Page Page Page Feeding sheets and towels Machine function, adjustment and troubleshootingDescription of machine functions General description of machine functionOperating the foot pedal option Advice Setting the temperatureSetting the speed Manual drive Guiding ironing belts Adjustments of the machineTightening the drive chain Tightening the ironing belts Tightening the feeding belts Adjusting the gap between input table and main roll Fault Cause Remedy TroubleshootingFault Condition Possible cause Fault Condition Solution After resetElectric heating control Temperature controlDescription of the control system General description of the control systemSpeed control Control of exhaust ventilatorStart/stop function Control panel and function keys Manual version Menu structure and how to enterMenu structure Manu adjusting menu Coin adjusting menu C2L coin 2 low Add XX defaultC1M coin 1 Medium C1H coin 1 HighTechnical menu Start PWM default Kp Xxxx default gas 300 default elecKd Xxxx default gas 1000 default elec Ki Xxxx default gas 0.5 default elecTMP REv Y/n default YES not adjustable with coinDiSP Display menuCentral panel Sigma explorerDaily maintenance MaintenanceSafety advice Maintenance schemeMonthly maintenance Weekly maintenancePage Page Half-yearly maintenance Feeding belts Drive Ironer beltsScrapers