Alliance Laundry Systems CI 1650/325 Description of the control system, Electric heating control

Page 44

6

Description of the control system

General description of the control system

The control system consists of a microprocessor board with built-on display and push-buttons.

Electric heating control

For the electric heated version, the relays for the heating elements are controlled by a time related P.I.D. controlled function built in the program of the processor, which has the opportunity of a quick reaction with limited overshoot. The elements are activated by relays.

Gas heating

With the gas version, a PWM controlled ventilator is used, which is controlled by the microprocessor.

This ventilator blows the mix of gas and air into the burner, which means that the power of the burner is controlled by the microprocessor. The advantage is that also here the burner is controlled with a P.I.D. controlled function from 20-40 to 100% so that there is a quick reacting system with a low overshoot.

When the need of power is lower than 15%, the burner will be temporarily switched off.

Temperature control

The temperature of the roll is measured by Pt1000 elements that are mounted on a contact plate on the roll. The Pt1000 are directly connected to the microprocessor board.

To prevent overheating when there is a malfunction of the Pt1000 or the microprocessor board,

a maximum temperature switch is placed, which switches off the power of the relay of the elements or the power of the gas control unit.

temp2: left sensor

temp1: right sensor

44

Image 44
Contents Part No. D1273 SeptemberPage Contents Safety Information Explanation of Safety MessagesPage Safety notice Important Safety Instructions Page Product description Intended useDescription of structural components Workplaces and noise level Technical data CI1650/325, CI2050/325 1650/325 2050/325Sound level measurement Warranty and service instructions Initial setup of the machine Transport and machine fasteningSetting up the machine 30 cmPage Page Page 16A Page Basic checks Ventilation of the roomAir filters Exhaust gasesOperation Operating devices and their positionStarting the machine Set the iron temperature FunctionsSet the ironing speed PedalReturn button not with guiding ribbons EndingFailure and information signals Page Page Page Machine function, adjustment and troubleshooting Description of machine functionsGeneral description of machine function Feeding sheets and towelsOperating the foot pedal option Setting the temperature AdviceSetting the speed Manual drive Adjustments of the machine Guiding ironing beltsTightening the drive chain Tightening the ironing belts Tightening the feeding belts Adjusting the gap between input table and main roll Fault Condition Possible cause TroubleshootingFault Cause Remedy After reset Fault Condition SolutionTemperature control Description of the control systemGeneral description of the control system Electric heating controlStart/stop function Control of exhaust ventilatorSpeed control Control panel and function keys Menu structure and how to enter Manual versionMenu structure Manu adjusting menu Coin adjusting menu Add XX default C1M coin 1 MediumC1H coin 1 High C2L coin 2 lowTechnical menu Kp Xxxx default gas 300 default elec Kd Xxxx default gas 1000 default elecKi Xxxx default gas 0.5 default elec Start PWM defaultREv Y/n default YES not adjustable with coin TMPDisplay menu Central panelSigma explorer DiSPMaintenance Safety adviceMaintenance scheme Daily maintenanceWeekly maintenance Monthly maintenancePage Page Half-yearly maintenance Feeding belts Ironer belts DriveScrapers