Alliance Laundry Systems CI 1650/325, CI 2050/325 Operation, Operating devices and their position

Page 24

4

Operation

Operating devices and their position

The machine is equipped with the following operating devices:

1: Emergency stop button

2: Gas failure reset button

3: Start/stop button

4: “+” Button

5: “-“ Button

6: Return button

7: Left display (temperature)

8: Right display (speed)

When the power is switched to the machine by the main switch, then “” and the program version will appear for 5 seconds.

Then the left display will give the actual temperature (in °C or °F) and the right display will give the actual speed (in M/min or ft/min).

24

Image 24
Contents Part No. D1273 SeptemberPage Contents Safety Information Explanation of Safety MessagesPage Safety notice Important Safety Instructions Page Product description Intended useDescription of structural components Workplaces and noise level Technical data CI1650/325, CI2050/325 1650/325 2050/325Sound level measurement Warranty and service instructions Initial setup of the machine Transport and machine fasteningSetting up the machine 30 cmPage Page Page 16A Page Basic checks Ventilation of the roomAir filters Exhaust gasesOperation Operating devices and their positionStarting the machine Set the iron temperature FunctionsSet the ironing speed PedalReturn button not with guiding ribbons EndingFailure and information signals Page Page Page Machine function, adjustment and troubleshooting Description of machine functionsGeneral description of machine function Feeding sheets and towelsOperating the foot pedal option Setting the temperature AdviceSetting the speed Manual drive Adjustments of the machine Guiding ironing beltsTightening the drive chain Tightening the ironing belts Tightening the feeding belts Adjusting the gap between input table and main roll Troubleshooting Fault Cause RemedyFault Condition Possible cause After reset Fault Condition SolutionTemperature control Description of the control systemGeneral description of the control system Electric heating controlControl of exhaust ventilator Speed controlStart/stop function Control panel and function keys Menu structure and how to enter Manual versionMenu structure Manu adjusting menu Coin adjusting menu Add XX default C1M coin 1 MediumC1H coin 1 High C2L coin 2 lowTechnical menu Kp Xxxx default gas 300 default elec Kd Xxxx default gas 1000 default elecKi Xxxx default gas 0.5 default elec Start PWM defaultREv Y/n default YES not adjustable with coin TMPDisplay menu Central panelSigma explorer DiSPMaintenance Safety adviceMaintenance scheme Daily maintenanceWeekly maintenance Monthly maintenancePage Page Half-yearly maintenance Feeding belts Ironer belts DriveScrapers