Electrical connection
All electrical connection work must be carried out by a qualified electrician in compliance with local and national regulations.
Connection should be made via a suitable isolator, with an
For extra safety it is advisable to in- stall a residual current device (RCD) with a trip current of 30 mA (DIN VDE 0664).
WARNING
THIS APPLIANCE MUST BE
EARTHED
For technical data see data plate or wiring diagram supplied.
The machine must only be operated with the voltage, frequency and fusing shown on the data plate.
The machine is not convertible.
The wiring diagram is to be found be- hind the cover plate on the left hand side, attached to the floor of the ma- chine.
The data plate with test certification is on the rear of the machine, and on the cover plate (behind the service panel).
To remove service panel and cover plate
Holding the service panel at the top right and bottom left hand corners, pull up out of its retainers and lift out at the bottom.
Isolate the machine from the power supply.
Unscrew the cover plate.
Pull off earth lead if necessary.