Miele G 7783 CD operating instructions

Page 6

Warning and safety instructions

Take care when handling liquids such as detergents, wetting

agents, or neutralising agents. These may contain irritant or corrosive ingre- dients, acids or alkalis. On no account use any organic solvent, as there may be the danger of an explosion occur- ring.

Follow the instructions and relevant safety procedures carefully. Wear pro- tective gloves and goggles.

Avoid inhalation of powder cleaners. They can cause burning

in the mouth and throat if swallowed, or inhibit breathing.

The water in the machine must not be used as drinking water.

Do not sit or lean on the open door, or rest objects on it. This could

cause the machine to tip and be dam- aged.

Be careful when sorting items with sharp pointed ends and position- ing them in the machine that you do not

hurt yourself or create danger for other operators.

When using this machine in the temperature ranges from 70 to

95°C be especially careful not to scald or burn yourself. Baskets and inserts must first cool down. Any water which may remain in containers will be very hot and must be emptied into the wash cabinet.

After drying with the TA drying unit then open the door to allow the items and in- serts to cool down.

Do not touch the heating elements during or directly after the end of a

programme, you could burn yourself.

Never use an ordinary or a high pressure hose on or in the vicinity

of the machine.

Before any maintenance or repair work is undertaken, the machine must be disconnected from the mains

supply, by switching off at the mains isolator, or withdrawing the mains fuse.

The following points should be ob- served to avoid damage to the ma- chine and the loads being cleaned.

The standard of disinfection in the Disinfection programmes must be confirmed by the user as a routine mat-

ter. The process should be regularly checked using chemical indicators, and bacteriologically at intervals using bio-indicators, with full documentation. Proceed according to local health auth- ority regulations.

Disinfection programmes must not be interrupted, as this can have a limiting effect on the disinfection result.

However, should an interruption be necessary. the complete programme must be repeated.

Only use cleaning agents formu- lated for special processes and ap-

proved by Miele for use with this ma- chine. Use of unsuitable cleaning agents could adversely affect the load or the machine.

6

Image 6
Contents CD Mielabor Contents Guide to the machine 10 11 12 13 Correct usage Page Page Accessories Disposal of an old machineDescription of the machine Available at extra costSetting the water softener Setting the WaterSoftenerReactivating the water softener, see Opening and closing the door To open the door aTo close the door Applications and loading Loading the machineRemoving excess soils Loading example Top basket frame can take various inserts 109106 Adjusting the top basket To adjust the top basketAdding Rinsing agent Setting the dosageRinsing agent Refilling with rinsing agentAdding neutralising agent and liquid detergent Adding neutralising agentAdding detergents Venting the liquid dispensing system / Maintenance Venting the liquid dispensing systemChecking the dispensing system Adding powder detergent Programme B, and when using O-175 or a pipette plate Adding detergentProgramme selection Programme chart = Cold7783 CD Instructions for the operatorPage Page Accessories 93C 70C Selecting an additional pro- gramme Switching the machine on and offSelecting a programme Programme ChangesSwitching the machine on and off Programme sequence indicator Switching offInterrupting a programme 1a. Cold water connection 1b. Hot water connection1c. AD water connection Programming special functions Reactivating the water softener Filling the salt containerSwitch on the machine Position the salt container as followsCleaning the coarse filter Cleaning and careCleaning the filters in the water cabinet Cleaning the fine, flat and micro-fine filtersCleaning the filters in the water inlet Drying unit TA cleaning and care Changing the Coarse FilterExchanging the S-class particle filter Correcting minor faults Faults/Possible CausesMachine does not start Installation Important for machines with DHK steam condensorPosition and secure the machine Cover plate worktop protection To remove service panel and cover plate Electrical connectionElectrical connection Plumbing Connection to the water inletAD connection to purified water, pressurised, 1.5 10 bar Connection to purified water non- pressurised 0 1.5 barDrainage Ventilation of the wash cabinet at rearCaring for the environment Disposal of the packing materialDisposal of your old machine Technical Data Noise emission in dB a