GAS REQUIREMENTS (GAS MODELS
CONNECTING GAS DRYERS
i ^ i^
•Gas supply requirements:
As shipped from the factory, this dryer is config- ured for use with (NG) natural gas. It can be con- vetted for use with LP (Liquefied Propane) gas. Gas pressure must not exceed 8 in. water column for (NG), or 13 in. water column for (LP).
. A qualified service or gas company technician must connect the dryer to the gas service. Failure to do so can result in fire, explosion, or death.
•Isolate the dryer from the gas supply system by closing its individual manual shutoff valve during any pressure testing of the gas supply. Failure to do so can result in fire, explosion, or death.
•Supply line requirements: Your laundry room must have a rigid gas supply line to your dryer. In the United States, an individual manual shutoff valve MUST be installed within at least 6 ft. (1.8 m) of the dryer, in accordance with the National Fuel Gas Code ANSI Z223.1 or Canadian gas installation code CSA B149.1. A 118 in. NPT pipe plug must be installed. Failure to do so can result in fire, explo- sion, or death.
•If using a rigid pipe, the rigid pipe should be 112 in. IPS. If acceptable under local codes and ordinances and when acceptable to your gas supplier, 318 in. approved tubing may be used where lengths are less than 20 ft. (6.1 m). Larger tubing should be used for lengths in excess of 20 ft. (6.1 m). Failure to do so can result in fire, explosion, or death.
ONLY)
•Connect the dryer to the type of gas shown on the nameplate. Failure to do so can result in fire, explo- sion, or death.
•To prevent contamination of the gas valve, purge the gas supply of air and sediment before connect- ing the gas supply to the dryer. Before tightening the connection between the gas supply and the dryer, purge remaining air until the odor of gas is
detected. Failure to do so can result in fire, explosion, or death.
•DO NOT use an open flame to inspect for gas leaks. Use a noncorrosive leak detection fluid. Failure to do
so can result in fire, explosion, or death.
•Use only a new AGA- or
to do so can result in fire, explosion, or death.
•Securely tic!hten all gas connections. Failure to do so can resuTt in fire, explosion, or death.
•Use Teflon tape or a
pipe threads. Failure to do so can result in fire, explo- sion, or death.
•DO NOT attempt any disassembly of the dryer; any disassembly requires the attention and tools of an authorized and qualified service person or company. Failure to do so can result in fire, explosion, or death.
Electrical Requirements for Gas Models Only
•Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Failure to follow this warning can result in fire, explosion, or death.
•For personal safety, this dryer must be properly grounded. Failure to follow this warning can result in fire, explosion, or death.
•The power cord of this dryer is equipped with a
10
This dryer must be plugged into a
grounded outlet protected by a
Where a standard
Ensure proper ground exists before use.
grounding
plug