Mitsubishi Electronics FR-A500L instruction manual Check Point Remedy

Page 42

 

 

 

PROTECTIVE FUNCTIONS

 

 

 

 

 

 

Operation Panel

 

Check Point

Remedy

 

Display

 

 

 

 

 

 

 

 

Is the usage frequency of the brake

Reduce the load GD2. Reduce the braking frequency.

 

 

Brake unit

unit appropriate?

Clean the cooling fins.

 

 

cooling fin

Are the cooling fins clogged?

 

 

overheating

Is there any error in the inverter unit

Replace the cooling fan.

 

 

 

cooling fan?

 

 

 

 

 

 

 

 

Control board

Is there an error in the cooling fan?

Replace the cooling fan.

 

 

ambient

Keep the ambient temperature within the

 

 

Is the ambient temperature too

 

 

temperature

specifications.

 

 

high?

 

 

error

 

 

 

 

 

 

 

 

Is there an output short circuit or

Repair the output short circuit and ground fault.

 

 

 

ground fault? (Check the motor

(Repair or replace the motor.)

 

 

 

winding and insulation resistance.)

Lengthen the deceleration time.

 

 

Output over

Was rapid acceleration attempted?

 

 

current

Did the load fluctuate suddenly?

Eliminate the sudden fluctuate in the load.

 

 

 

Was rapid deceleration attempted?

Lengthen the deceleration time.

 

 

 

Were the motor's mechanical

Investigate the braking operation.

 

 

 

brakes applied too quickly?

 

 

 

 

 

 

 

E.15

 

Is the cooling fan's power supply

Repair the short-circuited section.

 

 

Cooling fan

output short circuited?

 

 

 

power supply

Is the cooling fan's power supply

Replace the cooling fan power supply.

 

 

error

abnormal?

 

 

 

 

Is the fuse blown?

Replace the fuse.

 

 

 

 

 

 

 

 

Is the DC circuit short circuited?

Repair the short-circuited section, and replace the DC

 

 

Capacitor

 

fuse.

 

 

Is there an output short circuit or

Repair the output short circuit and ground fault.

 

 

overcurrent

 

 

ground fault? (Check the motor

(Repair or replace the motor.)

 

 

 

 

 

 

winding and insulation resistance.)

 

 

 

 

 

 

 

 

 

Is there an error in the cooling fan?

Replace the cooling fan.

 

 

 

Clean the cooling fins.

 

 

Cooling fin

Are the cooling fins clogged?

 

 

Keep the ambient temperature within the

 

 

overheat

Is the ambient temperature too

 

 

specifications.

 

 

 

high?

 

 

 

 

 

 

 

 

 

 

 

 

Is the gate output short circuited?

Repair the short-circuited section.

 

 

Gate power

Replace the control power supply board.

 

 

Is there an error in the control power

 

 

supply error

 

 

 

supply board?

 

 

 

 

 

 

 

 

 

 

 

zWhen the protective function is activated, take proper corrective action, reset the inverter, then resume operation.

31

Image 42
Contents FR-A500L This section is specifically about safety matters Electric Shock Prevention Fire PreventionInjury Prevention Additional instructions Transportation and installationWiring Trial runEmergency stop Maintenance, inspection and parts replacementOperation Disposing of the inverterContents Chapter Outline Wiring Precautions for operationInstallation Pre-Operation InformationNFB ELB Basic ConfigurationBasic configuration Name DescriptionChapter Installation Instructions for installationAt 5cm 1.97 inch Wiring Terminal connection diagramDescription of control circuit terminals Symbol Terminal Name DescriptionDescription of main circuit terminals Terminal Name Description,B,C RUNIPF Wiring of the main circuit Wiring instructionsTerminal block layout 800 2300P1, P, N Connection of the power supply and motor Connection procedureWiring of the control circuit NA version(OR Version)Changing the control logic RUN DC24V How to use terminals STOP, CS and PC Connection to the PU connector For RS-485 communicationDesign information Chapter Operation Chapter Parameters Parameter List ParametersDU/PU main display data selection F4 fourth frequency voltage 173 201 Can be accessed when Pr = Protective Functions Operation Parameter Errors AlarmsError alarm definitions Unit Name DescriptionSTP OHTOLT OPTCTE MB7Main circuit error E,15 details Charge AlarmName Details To know the operating status at the occurrence of alarm Correspondences between digital and actual charactersAlarm Code Alarm Output across B-C FR-DU04 Alarm code outputResetting the inverter Operation PanelTroubleshooting Checking the operation panel display at alarm stopOperation Panel Check Point Remedy Display Check Point Remedy Motor remains stopped Faults and check pointsSpeed greatly differs from the setting Motor rotates in opposite directionMotor current is large Operation mode is not changed properlyPower lamp is not lit Speed does not increaseCheck items Precautions for Maintenance and InspectionPrecautions for maintenance and inspection Periodic inspectionInsulation resistance test using megger Dielectric strength testDaily and Periodic Inspection Description Method Criterion Instrument DailyPreparation Checking methodModule device numbers and terminals to be checked Smoothing capacitors Replacement of partsCooling fan RelaysMeasurement of main circuit voltages, currents and power Measurement of voltages and currentsMeasuring Point Measuring Instrument 10VDC5VDC Chapter Specifications Standard specification Model specificationsCommon specifications Alarm FR-PU04Outline drawings FR-A540L-450K, 375KFR-A540L-540K~800K SDA P5S RDB RDA SDBAppendices Appendix AppendixFront Wiring between cooling fan and terminals is as follows Check the air flow directionEF-40ETB R G Converter EF-30ETB Control Inverter Resistor Temperature Abnormal Signals MT-BR5MT-BR5 TH1 TH2 PR PR EShipment case example
Related manuals