Mitsubishi Electronics FR-A500L instruction manual Standard specification, Model specifications

Page 53

6.1Standard specification

SPECIFICATIONS

6.1.1 Model specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Note 8)

(Note 8)

 

Model FR-A540L-

□□□

K-NA

375

 

450

 

530

 

600

 

670

 

750

800

 

 

 

 

 

 

 

 

Applicable motor

 

Constant torque

375

 

450

 

530

 

600

 

670

 

750

800

capacity (kW) (Note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable torque

450

 

530

 

600

 

670

 

750

 

800

900

 

Rated capacity (HP)

 

Constant torque

600

 

700

 

800

 

900

 

1000

 

1150

1250

 

(Note 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable torque

700

 

800

 

900

 

1000

 

1150

 

1250

1400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated current (A)

 

Constant torque

722

 

866

 

1010

 

1152

 

1296

 

1440

1584

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

Variable torque

866

 

1010

 

1152

 

1296

 

1440

 

1534

1728

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150% 60 sec., 200%

 

 

 

 

 

 

 

 

 

 

Constant torque

0.5 sec. (inverse-time

 

150% 60 sec. (inverse-time characteristics)

 

Overload capacity

 

 

 

characteristics)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120% 60 sec., 150%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable torque

0.5 sec. (inverse-time

 

120% 60 sec. (inverse-time characteristics)

 

 

 

 

 

characteristics)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

Three phase, 380-480V 5060Hz

 

 

 

Rated input AC voltage, frequency

 

 

 

 

Three phase, 380-480V 50 60Hz

 

 

supply

 

 

 

 

 

 

 

 

 

 

Tolerable AC voltage fluctuation

 

 

 

 

323-528V 50

60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Tolerable frequency fluctuation

 

 

 

 

 

±5%

 

 

 

 

 

Power facility

 

Constant torque

550

 

660

 

770

 

878

 

988

 

1097

1210

 

 

 

 

 

 

 

 

capacity (kVA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable torque

660

 

770

 

878

 

988

 

1097

 

1210

1320

 

 

 

 

 

 

 

 

 

 

 

 

 

Protective structure (JEM 1030)

Open type (IP00)

 

 

 

Open type (IP20)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-10°C to 40° C

 

 

 

 

 

 

 

 

 

 

Ambient temperature

 

 

 

(14° F to 104° F) at VT

-10°C to 40° C (14° F to 104° F)

 

 

 

 

 

-10°C to 50° C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(14° F to 122° F) at CT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling method

 

 

 

 

 

 

 

 

Forced air cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approx. weight (kg (lb) )

 

 

 

490

 

500

 

1060

 

1060

 

1100

 

1100

1200

 

 

 

(1078)

 

(1100)

 

(2332)

 

(2332)

 

(2420)

 

(2420)

(2640)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: 1. The applicable motor capacity indicated is the maximum capacity applicable when Mitsubishi 4- pole standard motor is used For A540K.

2.The rated output capacity indicated is based on for A540L.

3.The overload capacity indicated in % is the ratio of the overload current to the inverter’s rated current. For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.

4.The maximum output voltage cannot exceed the power supply voltage. The maximum output voltage may be set as desired below the power supply voltage.

5.The power supply capacity changes with the values of the power supply side inverter impedance (including those of the input reactor and cables).

6.For use in Variable torque mode, refer to Pr. 570.

7.For inverter environmental conditions (including ambient temperature) please check page A-3.

8.Preliminary ratings.

41

Image 53
Contents FR-A500L This section is specifically about safety matters Injury Prevention Electric Shock PreventionFire Prevention Wiring Transportation and installationAdditional instructions Trial runOperation Maintenance, inspection and parts replacementEmergency stop Disposing of the inverterContents Chapter Outline Installation Precautions for operationWiring Pre-Operation InformationBasic configuration Basic ConfigurationNFB ELB Name DescriptionChapter Instructions for installation InstallationAt 5cm 1.97 inch Terminal connection diagram WiringDescription of main circuit terminals Symbol Terminal Name DescriptionDescription of control circuit terminals Terminal Name DescriptionIPF ,B,CRUN Wiring instructions Wiring of the main circuit800 2300 Terminal block layoutP1, P, N Connection procedure Connection of the power supply and motorNA version(OR Version) Wiring of the control circuitChanging the control logic RUN DC24V How to use terminals STOP, CS and PC For RS-485 communication Connection to the PU connectorDesign information Chapter Operation Chapter Parameters Parameters Parameter ListDU/PU main display data selection F4 fourth frequency voltage 173 201 Can be accessed when Pr = Protective Functions Error alarm definitions Errors AlarmsOperation Parameter Unit Name DescriptionOLT OHTSTP OPTMB7 CTEName Details Main circuit error E,15 detailsCharge Alarm Correspondences between digital and actual characters To know the operating status at the occurrence of alarmResetting the inverter Alarm code outputAlarm Code Alarm Output across B-C FR-DU04 Operation PanelOperation Panel Check Point Remedy Display TroubleshootingChecking the operation panel display at alarm stop Check Point Remedy Speed greatly differs from the setting Faults and check pointsMotor remains stopped Motor rotates in opposite directionPower lamp is not lit Operation mode is not changed properlyMotor current is large Speed does not increasePrecautions for maintenance and inspection Precautions for Maintenance and InspectionCheck items Periodic inspectionDielectric strength test Insulation resistance test using meggerDescription Method Criterion Instrument Daily Daily and Periodic InspectionModule device numbers and terminals to be checked PreparationChecking method Cooling fan Replacement of partsSmoothing capacitors RelaysMeasurement of voltages and currents Measurement of main circuit voltages, currents and power5VDC Measuring Point Measuring Instrument10VDC Chapter Specifications Model specifications Standard specificationCommon specifications FR-PU04 AlarmFR-A540L-450K, 375K Outline drawingsFR-A540L-540K~800K P5S RDB RDA SDB SDAAppendices Front AppendixAppendix EF-40ETB R G Converter EF-30ETB Control Inverter Wiring between cooling fan and terminals is as followsCheck the air flow direction MT-BR5MT-BR5 TH1 TH2 PR PR E Resistor Temperature Abnormal SignalsShipment case example