Mitsubishi Electronics FR-A500L instruction manual Contents

Page 6

 

CONTENTS

 

1 OUTLINE

1

1.1 Pre-Operation Information

1

1.1.1

Precautions for operation

1

1.2 Basic Configuration

2

1.2.1

Basic configuration

2

2 INSTALLATION AND WIRING

3

2.1 Installation

3

2.1.1

Instructions for installation

3

2.2 Wiring

5

2.2.1

Terminal connection diagram

5

2.2.2 Wiring of the main circuit

8

2.2.3 Wiring of the control circuit

12

2.2.4 Connection to the PU connector

16

2.2.5

Design information

17

3 OPERATION

17

4 PARAMETER

18

4.1. Parameter list

18

5 PROTECTIVE FUNCTIONS

24

5.1 Errors (Alarms)

24

5.1.1

Error (alarm) definitions

24

5.1.2 Correspondences between digital and actual characters

28

5.1.3

Alarm code output

29

5.1.4

Resetting the inverter

29

5.2 Troubleshooting

30

5.2.1 Checking the operation panel display at alarm stop

30

5.2.2

Faults and check points

32

5.3 Precautions for Maintenance and Inspection

34

5.3.1 Precautions for maintenance and inspection

34

5.3.2

Check items

34

5.3.3

Periodic inspection

34

5.3.4 Insulation resistance test using megger

35

5.3.5

Dielectric strength test

35

5.3.6

Replacement of parts

38

5.3.7 Measurement of main circuit voltages, currents and power

39

6 SPECIFICATIONS

41

6.1 Standard Specifications

41

6.1.1

Model specifications

41

6.1.2

Common specifications

42

6.1.3

Outline drawings

44

APPENDICES

45

Appendix3

47

Appendix4

49

Appendix5

50

Image 6
Contents FR-A500L This section is specifically about safety matters Electric Shock Prevention Fire PreventionInjury Prevention Additional instructions Transportation and installationWiring Trial runEmergency stop Maintenance, inspection and parts replacementOperation Disposing of the inverterContents Chapter Outline Wiring Precautions for operationInstallation Pre-Operation InformationNFB ELB Basic ConfigurationBasic configuration Name DescriptionChapter Installation Instructions for installationAt 5cm 1.97 inch Wiring Terminal connection diagramDescription of control circuit terminals Symbol Terminal Name DescriptionDescription of main circuit terminals Terminal Name Description,B,C RUNIPF Wiring of the main circuit Wiring instructionsTerminal block layout 800 2300P1, P, N Connection of the power supply and motor Connection procedureWiring of the control circuit NA version(OR Version)Changing the control logic RUN DC24V How to use terminals STOP, CS and PC Connection to the PU connector For RS-485 communicationDesign information Chapter Operation Chapter Parameters Parameter List ParametersDU/PU main display data selection F4 fourth frequency voltage 173 201 Can be accessed when Pr = Protective Functions Operation Parameter Errors AlarmsError alarm definitions Unit Name DescriptionSTP OHTOLT OPTCTE MB7Main circuit error E,15 details Charge AlarmName Details To know the operating status at the occurrence of alarm Correspondences between digital and actual charactersAlarm Code Alarm Output across B-C FR-DU04 Alarm code outputResetting the inverter Operation PanelTroubleshooting Checking the operation panel display at alarm stopOperation Panel Check Point Remedy Display Check Point Remedy Motor remains stopped Faults and check pointsSpeed greatly differs from the setting Motor rotates in opposite directionMotor current is large Operation mode is not changed properlyPower lamp is not lit Speed does not increaseCheck items Precautions for Maintenance and InspectionPrecautions for maintenance and inspection Periodic inspectionInsulation resistance test using megger Dielectric strength testDaily and Periodic Inspection Description Method Criterion Instrument DailyPreparation Checking methodModule device numbers and terminals to be checked Smoothing capacitors Replacement of partsCooling fan RelaysMeasurement of main circuit voltages, currents and power Measurement of voltages and currentsMeasuring Point Measuring Instrument 10VDC5VDC Chapter Specifications Standard specification Model specificationsCommon specifications Alarm FR-PU04Outline drawings FR-A540L-450K, 375KFR-A540L-540K~800K SDA P5S RDB RDA SDBAppendices Appendix AppendixFront Wiring between cooling fan and terminals is as follows Check the air flow directionEF-40ETB R G Converter EF-30ETB Control Inverter Resistor Temperature Abnormal Signals MT-BR5MT-BR5 TH1 TH2 PR PR EShipment case example