Gefen EXT-IP-2-RS2322 user manual Installation, Connection Instructions, Sample Wiring Diagram

Page 14

Getting Started

Installation

Connection Instructions

1.Connect an Ethernet cable between the IP-based control device and the IP control port on the IP to 2 x RS-232 Converter.

An Ethernet switch can also exist between the IP to 2 x RS-232 Converter and the IP-based control device (see Sample Wiring Diagram below).

2.Connect an RS-232 device to each of the RS-232 ports (RS-232 1 and RS-232 2) on the IP to 2 x RS-232 Converter.

3.Connect the included 5V DC locking power supply to the 5V DC power receptacle on the IP to 2 x RS-232 Converter. Do not overtighten the locking power connectors.

4.Connect the AC power cord from the power supply to an available electrical outlet.

Sample Wiring Diagram

DB-9 CABLE

CAT-5 CABLE

IP-based Automation

Control Device

Ethernet Switch

RS-232-enabled

Device

EXT-IP-2-RS2322

RS-232-enabled

Device

EXT-IP-2-RS2322

page 4

Image 14 Contents
IP to RS-232 Important Safety Instructions Warranty Information Contacting Gefen Technical Support Operating Notes Web sitePacking List Features and Packing ListFeatures Vii Table of Contents Page Page Getting Started IP to 2xRS-232 Converter IntroductionIntroduction Connection Instructions InstallationSample Wiring Diagram Page Page Advanced Operation RS-232 and IP Configuration Configuration using the Gefen Discovery ToolConfiguration using RS-232 Diagram 2.1 Configuration using a null-modem cableInformation Commands Commands #help ExampleAdvanced Operation #setadddelim #setdevicedescr #setenddel #setgateway #sethttpport #setipadd #setnetmask #setsendbytecnt #setsendtimeout #setserialdescr #setserialmode #setserialparams Baud Rate = 19200 Bps Line Delay = 1000 ms #setstartdel #settcpbrport #settcptermport #settelnetpass #setudpbrport #setudpechobr #setudpport #setudpremotebr #setudprip #setudprport #showdelprms #showdevicedescr #showipconfig #showme #showserialdescr #showserialmode #showserialparams #showtelnetpass #showverdata #systemwidereset Param1 Value#usediscovery #usetcpaccess #usetcptermpass #useudpaccess #useudpecho Help Using the built-in Web InterfaceWeb Interface Select RS-232 Port RS-232 ModeRS-232 DescriptionParity Baud RateData Bits Stop BitsForce Send bytes Line Delay msForce Send ms Start Delimiter Value Add Delimiters to data sentUse Start Delimiter Use End DelimiterUDP Local Port End Delimiter ValueTCP Port Destination Port Set DefaultsDestination IP UDP EchoMode Network tabMAC Address IP AddressGateway Http PortOld Password Enable TCP AccessRequire Password on Connect User NameTerminal Port New PasswordConfirm Password UDP Port Enable UDP AccessEnable UDP Echo Destination UDP Port Enable DiscoveryDestination UDP IP Address Restore Download Download Current ConfigurationBrowse... Restore Configuration System tabFactory Reset Browse... Firmware UpdateUpdate ResetPage Appendix Default Settings RS-232 SettingsIP Settings NetworkSpecifications Connectors, Indicators, and Controls RS-232Page Nordhoff St., Chatsworth CA