Gefen EXT-IP-2-RS2322 user manual #setsendbytecnt

Page 32

Advanced Operation

Commands

#set_send_byte_cnt

Sets the send-byte count value for bridging mode.

Syntax

#set_send_byte_cnt param1

Parameters

param1

Serial port

[1

... 2]

param2

Byte count

[0

... 255]

Example

#set_send_byte_cnt 1 100

UART 1 bridging send byte count limit is set to 100 bytes

Related Commands

#set_add_delim #set_end_del #set_serial_mode #set_start_del

page 22

Image 32 Contents
IP to RS-232 Important Safety Instructions Warranty Information Contacting Gefen Technical Support Operating Notes Web sitePacking List Features and Packing ListFeatures Vii Table of Contents Page Page Getting Started IP to 2xRS-232 Converter IntroductionIntroduction Connection Instructions InstallationSample Wiring Diagram Page Page Advanced Operation RS-232 and IP Configuration Configuration using the Gefen Discovery ToolConfiguration using RS-232 Diagram 2.1 Configuration using a null-modem cableInformation Commands Commands #help ExampleAdvanced Operation #setadddelim #setdevicedescr #setenddel #setgateway #sethttpport #setipadd #setnetmask #setsendbytecnt #setsendtimeout #setserialdescr #setserialmode #setserialparams Baud Rate = 19200 Bps Line Delay = 1000 ms #setstartdel #settcpbrport #settcptermport #settelnetpass #setudpbrport #setudpechobr #setudpport #setudpremotebr #setudprip #setudprport #showdelprms #showdevicedescr #showipconfig #showme #showserialdescr #showserialmode #showserialparams #showtelnetpass #showverdata #systemwidereset Param1 Value#usediscovery #usetcpaccess #usetcptermpass #useudpaccess #useudpecho Help Using the built-in Web InterfaceWeb Interface RS-232 Mode RS-232Select RS-232 Port DescriptionBaud Rate Data BitsParity Stop BitsForce Send bytes Line Delay msForce Send ms Add Delimiters to data sent Use Start DelimiterStart Delimiter Value Use End DelimiterUDP Local Port End Delimiter ValueTCP Port Set Defaults Destination IPDestination Port UDP EchoNetwork tab MAC AddressMode IP AddressGateway Http PortEnable TCP Access Require Password on ConnectOld Password User NameTerminal Port New PasswordConfirm Password UDP Port Enable UDP AccessEnable UDP Echo Destination UDP Port Enable DiscoveryDestination UDP IP Address Download Download Current Configuration Browse... Restore ConfigurationRestore System tabBrowse... Firmware Update UpdateFactory Reset ResetPage Appendix Default Settings RS-232 SettingsIP Settings NetworkSpecifications Connectors, Indicators, and Controls RS-232Page Nordhoff St., Chatsworth CA