Gefen EXT-IP-2-RS2322 user manual #setstartdel

Page 38

Advanced Operation

Commands

#set_start_del

Sets the Start Delimiter mode and value for the specified serial port. The Start Delimiter must always be specified before the End Delimiter.

Syntax

#set_start_del param1 param2 param3

Parameters

param1

Serial port

 

 

[1 ... 2]

 

param2

State

 

 

[0 ... 1]

 

 

Mode

 

Description

 

 

 

 

 

 

 

1

 

TCP bridge

 

 

 

2

 

UDP bridge

 

 

 

3

 

Terminal mode

 

 

param3

Start delimiter

[00 ... FF]

Example

#set_start_del 1 1 a0

Start delimiter set to ON with a value of a0

Related Commands

#set_add_delim #set_end_del

page 28

Image 38 Contents
IP to RS-232 Important Safety Instructions Warranty Information Contacting Gefen Technical Support Operating Notes Web sitePacking List Features and Packing ListFeatures Vii Table of Contents Page Page Getting Started IP to 2xRS-232 Converter IntroductionIntroduction Connection Instructions InstallationSample Wiring Diagram Page Page Advanced Operation RS-232 and IP Configuration Configuration using the Gefen Discovery ToolConfiguration using RS-232 Diagram 2.1 Configuration using a null-modem cableInformation Commands Commands #help ExampleAdvanced Operation #setadddelim #setdevicedescr #setenddel #setgateway #sethttpport #setipadd #setnetmask #setsendbytecnt #setsendtimeout #setserialdescr #setserialmode #setserialparams Baud Rate = 19200 Bps Line Delay = 1000 ms #setstartdel #settcpbrport #settcptermport #settelnetpass #setudpbrport #setudpechobr #setudpport #setudpremotebr #setudprip #setudprport #showdelprms #showdevicedescr #showipconfig #showme #showserialdescr #showserialmode #showserialparams #showtelnetpass #showverdata #systemwidereset Param1 Value#usediscovery #usetcpaccess #usetcptermpass #useudpaccess #useudpecho Help Using the built-in Web InterfaceWeb Interface Select RS-232 Port RS-232 ModeRS-232 DescriptionParity Baud RateData Bits Stop BitsForce Send bytes Line Delay msForce Send ms Start Delimiter Value Add Delimiters to data sentUse Start Delimiter Use End DelimiterUDP Local Port End Delimiter ValueTCP Port Destination Port Set DefaultsDestination IP UDP EchoMode Network tabMAC Address IP AddressGateway Http PortOld Password Enable TCP AccessRequire Password on Connect User NameTerminal Port New PasswordConfirm Password UDP Port Enable UDP AccessEnable UDP Echo Destination UDP Port Enable DiscoveryDestination UDP IP Address Restore Download Download Current ConfigurationBrowse... Restore Configuration System tabFactory Reset Browse... Firmware UpdateUpdate ResetPage Appendix Default Settings RS-232 SettingsIP Settings NetworkSpecifications Connectors, Indicators, and Controls RS-232Page Nordhoff St., Chatsworth CA