Gefen EXT-IP-2-RS2322 user manual Commands

Page 21

Advanced Operation

Commands

Command

Description

#help

Displays a list of all available commands

#set_add_delim

Enables or disables option to add delimiter to data

#set_device_descr

Sets the device description

#set_end_del

Sets the end frame delimiter

#set_gateway

Sets the gateway (router) IP address

#set_http_port

Sets the HTTP listening port of the IP to RS-232

 

Converter

#set_ipadd

Sets the IP address of the IP to RS-232 Converter

#set_netmask

Sets the subnet mask of the IP to RS-232 Converter

#set_send_byte_cnt

Sets the send-byte count value for bridging mode

#set_send_time_out

Sets the time-out value for sending data

#set_serial_descr

Assigns a description to the specified RS-232 port

#set_serial_mode

Sets the serial mode (TCP, UDP, or Terminal)

#set_serial_params

Assigns the settings to the specified RS-232 port

#set_start_del

Sets the Start Frame delimiter

#set_tcp_br_port

Sets the TCP bridge listening port

#set_tcp_term_port

Sets the TCP terminal listening port

#set_telnet_pass

Sets the TCP terminal password

#set_udp_br_port

Sets the UDP bridge listening port

#set_udp_echo_br

Enables or disables UDP bridge echo

#set_udp_port

Sets the UDP listening port

#set_udp_remote_br

Assigns the UDP bridge settings for the specified

 

RS-232 port

#set_udp_rip

Sets the remote UDP IP address

#set_udp_rport

Sets the UDP remote port

#show_del_prms

Dusplays the current delimiter parameters for the

 

specified serial port

#show_device_descr

Displays the device description

#show_ipconfig

Displays the current TCP/IP and UDP settings of the IP

 

to 2 x RS-232 Converter

#show_me

Enables or disables the flashing of the LED on the

 

device

#show_serial_descr

Displays the current description of the specified RS-232

 

port

#show_serial_mode

Displays the mode of the specified RS-232 port

(continued on next page)

page 11

Image 21 Contents
IP to RS-232 Important Safety Instructions Warranty Information Contacting Gefen Technical Support Web site Operating NotesFeatures and Packing List FeaturesPacking List Vii Table of Contents Page Page Getting Started Introduction IP to 2xRS-232 ConverterIntroduction Installation Sample Wiring DiagramConnection Instructions Page Page Advanced Operation Configuration using the Gefen Discovery Tool RS-232 and IP ConfigurationDiagram 2.1 Configuration using a null-modem cable Configuration using RS-232Information Commands Commands Example #helpAdvanced Operation #setadddelim #setdevicedescr #setenddel #setgateway #sethttpport #setipadd #setnetmask #setsendbytecnt #setsendtimeout #setserialdescr #setserialmode #setserialparams Baud Rate = 19200 Bps Line Delay = 1000 ms #setstartdel #settcpbrport #settcptermport #settelnetpass #setudpbrport #setudpechobr #setudpport #setudpremotebr #setudprip #setudprport #showdelprms #showdevicedescr #showipconfig #showme #showserialdescr #showserialmode #showserialparams #showtelnetpass #showverdata Param1 Value #systemwidereset#usediscovery #usetcpaccess #usetcptermpass #useudpaccess #useudpecho Using the built-in Web Interface Web InterfaceHelp RS-232 RS-232 ModeSelect RS-232 Port DescriptionData Bits Baud RateParity Stop BitsLine Delay ms Force Send msForce Send bytes Use Start Delimiter Add Delimiters to data sentStart Delimiter Value Use End DelimiterEnd Delimiter Value TCP PortUDP Local Port Destination IP Set DefaultsDestination Port UDP EchoMAC Address Network tabMode IP AddressHttp Port GatewayRequire Password on Connect Enable TCP AccessOld Password User NameNew Password Confirm PasswordTerminal Port Enable UDP Access Enable UDP EchoUDP Port Enable Discovery Destination UDP IP AddressDestination UDP Port Browse... Restore Configuration Download Download Current ConfigurationRestore System tabUpdate Browse... Firmware UpdateFactory Reset ResetPage Appendix RS-232 Settings Default SettingsNetwork IP SettingsConnectors, Indicators, and Controls RS-232 SpecificationsPage Nordhoff St., Chatsworth CA