VOR/ILS Analyzer EVS200

 

 

 

 

Chapter 3: Operation

Command AM7

 

 

 

 

 

 

 

 

 

Kommando

Funktion

 

 

 

AM6

<AM-modulation depth ID>

query of AM-modulation depth ID

 

 

 

The command AM7 reads the actual AM-modulation depth (ID) in the BEACON mode.

Example:

 

 

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM7 <CR>

e.g.

10.2% <CR/LF>

 

am7 <CR>

e.g.

10.2% <CR/LF>

Command AF4

command

function

 

AF4

<AF-frequency range F1>

query of AF-frequency 3000 Hz

 

The command AF4 reads the actual AF frequency (F1) in the BEACON mode.

Example:

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AF4 <CR>

e.g.

3000.0Hz <CR/LF>

 

af4 <CR>

e.g.

3000.0Hz <CR/LF>

Command AF5

command

function

 

AF5

<AF-frequency range F2>

query of AF-frequency 1300 Hz

 

The command AF5 reads the actual AF frequency (F2) in the BEACON mode.

Example:

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AF5 <CR>

e.g.

1300.0Hz <CR/LF>

 

af5 <CR>

e.g.

1300.0Hz <CR/LF>

0796.1800.02

E-8

51

Page 60
Image 60