VOR/ILS Analyzer EVS200
Chapter 3: Operation
Command AF8
command | function |
AF8 |
|
|
|
The command AF8 reads the actual AF frequency (ID) in the ILS /VOR mode.
Prediction for reading out the data of the corresponding mode (VOR/ILS) is the switching over to display2.
Example: |
|
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 | |
query: | AF8 <CR> | e.g. | 1020.0Hz <CR/LF> |
| af8 <CR> | e.g.. | 1020.0Hz <CR/LF> |
Command AM8
command | function |
AM8 | query of |
|
|
The command AM8 reads the actual
Prediction for reading out the data of the corresponding mode (VOR/ILS) is the switching over to display2.
Example: |
|
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 | |
query: | AM8 <CR> | e.g. | 10.0% <CR/LF> |
| am8 <CR> | e.g. | 10.0% <CR/LF> |
Command AM9
command | function |
AM9 | query of |
|
|
The command AM9 reads the actual
mode.
Prediction for reading out the data of the corresponding mode (VOR/ILS) is the switching over to display2.
Example: |
|
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 | |
query: | AM9 <CR> | e.g. | 09.6% <CR/LF> |
| am9 <CR> | e.g. | 09.6% <CR/LF> |
|
|
| |
|
|
| |
0796.1800.02 | 43 |