VOR/ILS Analyzer EVS200

Chapter 3: Operation

Command AF8

command

function

AF8 <AF-frequency ID>

AF-frequency ID query

 

 

The command AF8 reads the actual AF frequency (ID) in the ILS /VOR mode.

Prediction for reading out the data of the corresponding mode (VOR/ILS) is the switching over to display2.

Example:

 

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AF8 <CR>

e.g.

1020.0Hz <CR/LF>

 

af8 <CR>

e.g..

1020.0Hz <CR/LF>

Command AM8

command

function

AM8 <AM-modulation depth (ID)>

query of AM-modulation depth (ID)

 

 

The command AM8 reads the actual AM-modulation depth (ID) in the ILS / VOR mode.

Prediction for reading out the data of the corresponding mode (VOR/ILS) is the switching over to display2.

Example:

 

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM8 <CR>

e.g.

10.0% <CR/LF>

 

am8 <CR>

e.g.

10.0% <CR/LF>

Command AM9

command

function

AM9 <AM-modulation depth (voice)>

query of AM-modulation depth (voice)

 

 

The command AM9 reads the actual AM-modulation depth (voice 300 Hz to 3kHz) in the ILS / VOR

mode.

Prediction for reading out the data of the corresponding mode (VOR/ILS) is the switching over to display2.

Example:

 

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM9 <CR>

e.g.

09.6% <CR/LF>

 

am9 <CR>

e.g.

09.6% <CR/LF>

 

 

 

 

 

 

0796.1800.02

E-8

43

Page 52
Image 52
Procom EVS200 Command AF8 Function, Command AM8 Function, Command AM9 Function, AF8 AF-frequency ID AF-frequency ID query