VOR/ILS Analyzer EVS200

Chapter 3: Operation

Operation

Switch On/switch Off the unit at mains supply

￿With the mains switch at the rearside switch the unit on or off.

￿With the switch "POWER" at the front side switch the unit on or "STANDBY".

On switch position "STANDBY" the in- stalled battery (option) will be charged. Details see item "Battery Operation"

(page 12).

Switch On/switch Off the unit at VDC supply

When the unit is supplied from the installed battery (option) or through the external DC input it must be switched on or to "STANDBY" only with the Switch "POWER" at the frontside.

On external DC supply of the unit the installed battery

(option) will not be charged!

Switch on procedure

During the switch on procedure the VOR/ILS Analyzer EVS200 performs a selftest (BITE). The tested functions are indicated with "OK". This test takes approx. 5 s. After that automatically it is switched over to the startup mode which was set in the setup.

Because of the displayed battery voltage

(U BATT) it is possible to value the charging￿ state of the installed battery (option).

Malfunctions of the BITE will be indicated by "FAIL". In that case the unit does not switch over to the startup mode (see also item "Selftest").

0796.1800.02

E-8

11

Page 20
Image 20