VOR/ILS Analyzer EVS200
Chapter 3: Operation
Command MI
command | function | |
MI | ILS mode setting | |
| ||
The command MI enables the switching over to the "ILS“ mode. | ||
Example: |
| |
| command from the controller | response of the VOR/ILS Analyzer EVS200 |
input: | MI <CR> | READY <CR/LF> |
| mi <CR> | READY <CR/LF> |
Command MB
command | function | |
MB | BEACON mode setting | |
| ||
The command MB enables the switching over to the "BEACON mode“. | ||
Example: |
| |
| command from the controller | response of the VOR/ILS Analyzer EVS200 |
input: | MB <CR> | READY <CR/LF> |
| mb <CR> | READY <CR/LF> |
Mode related control commands
ILS-Mode
Command DD0
command | function |
DD0 <DDM information> | DDM value query |
|
|
The command DD0 reads the actual DDM value (value without dimension) in the ILS mode.
Example: |
|
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 | |
query: | DD0 <CR> | e.g. | 0.2008 <CR/LF> |
| dd0 <CR> | e.g. | 0.2008 <CR/LF> |
0796.1800.02 | 35 |