VOR/ILS Analyzer EVS200

 

 

Chapter 3: Operation

Command FA3

 

 

 

 

 

command

function

 

FA3 <Fast DDM measuring on>

Activating the Fast DDM measurement

 

 

 

 

 

The command FA3 switches on the fast DDM measurement. The measuring, used only for landing path measurement can only be activated through a controller. The command FA3 performs the con- tinuous measurement and output of the DDM, RF level, Modfactor 90 Hz and Modfactor 150 Hz. The 50-ms measurement interval consists of DSP analysis, DSP data transmission to the host processor and conversion of the DSP raw measurement value into DDM, dBm and AM %. The measurement values output is performed in this mode as interrupt operation via RS232 interface.

In this Fast-Mode (FA3) a measurement value set will only be transmitted to the PC if it is demanded by a short command (1 ASCII-Character). The response from the EVS200 is performed without a longer delay within about 15 to 20 ms between measurement value demand and measurement value transmission. The stated RS-232-transmission times are related to 19.200 Baud.

The measurement values can be read in and output as a text file corresponding to the terminal pro- gram.

The baud rate must be set to 19200 baud in the Setup of the VOR/ILS Analyzer

EVS200. It must be attended the acceptance of the data transfering rate by the terminal program.

￿The measurement can be stopped through the command FA0 (refer to Command FA0) or <CR>.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

 

input:

e.g. A

 

output form: (DDM <CR >, RF level <CR >,

 

￿

Demand for measurement

 

AM90 <CR >, AM 150 <CR >)

 

output form as FA2

 

 

values output:

 

all ASCII characters without:

example:

-0001 <CR > (DDM),

 

CR (0Dh), LF (0Ah), # (23h), @ (40h)

 

 

 

 

-412 <CR > (RF level),

With the command FA3 the echo

201 <CR > (AM90),

mode is automatically switched

202 <CR > (AM150),

OFF.

 

1/90Hz = 11.1msec.

 

 

 

N

N+1

N+2

 

N+3

N+4

 

N+5

 

N+6

N+7

 

 

N+8

 

N+9

N+10

DSP-Analysis

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Programm-Interrupt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA-Transfer

 

DDM, AM90, AM150,

 

DATA-Transfer

DDM, AM90,

 

 

 

AM150,

 

DATA-

 

 

 

 

 

 

 

RF-Level - Calculation

 

RF-Level -

 

 

 

 

Calculation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS232-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transfer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15...20 msec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Request fromPCl

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to EVS200 (RXD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Answer to PCl

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fromEVS200 (TXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 msec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 