VOR/ILS Analyzer EVS200

Chapter 2: Preparation for Operation

External AF input

Via the AF input (AF-EXT) at the rear side the unit can be fed with an AF signal for further analysis of typical AF parameters (e.g. level, frequency). This is very applicable for receivers which cannot per- form AF analysis.

input level: approx.: 1 to 2 Vrms / 50 Ω e.g. VOR/ILS Analyzer ￿=external receiver

Connection AF-EXT of the VOR/ILS Analyzer EVS200 with the AF output of an external receiver

DSP output

On the DSP-OUT at the rearside e.g. a XY-tracer can be connected. The scaling of the XY values can be set for any mode (localizer/glideslope) in the setup (DDM Y / t-RANGE)or in ILS-Mode

(Y / t-SETUP).

output signals in VOR- and ILS-Mode:

 

ILS-Mode

VOR-Mode

 

 

 

Display 1

normalized DDM-values

no output

 

(DC-voltage)

 

 

Range 1 to 4

 

Display 2

voice-frequency

voice-frequency

 

(300 to 3000 Hz)

(300 to 3000 Hz)

 

 

 

(corresponding

 

 

 

 

DC voltage)

scaling in the setup:

 

 

 

 

 

 

(0 V ±5 mV)

0 DDM

(1 V ±5 mV)

Localizer

Glideslope

 

 

 

 

 

Range 1

0.0

±25%

0.0 ±50%

 

 

 

0 ±0.25 DDM

0.0 ±0.5 DDM

 

 

Range 2

0.0

±2.5%

0.0 ±5%

 

 

 

0 ±0.025 DDM

0.0 ±0.05 DDM

 

 

Range 3

0.0

±2.58%

8.75 ±5%

 

 

 

0.0 ±0.0258 DDM

0.0875 ±0.05 DDM

 

 

Range 4

0.0

±50%

17.5 +5%

 

 

 

0.0 ±0.5 DDM

0.175 +0.05 DDM

0796.1800.02

E-8

10

Page 19
Image 19