VOR/ILS Analyzer EVS200
0796.1800.02 E-8 49
Chapter 3: Operation
∆
∆∆
∆Level-Mode
Command SR
command function
SR <Set REF> reference level setting
The command SR is for setting the actual receiver level as a reference level in the reference level
window "∆
∆∆
∆level"-mode.
Example: command from the controller response of the VOR/ILS Analyzer EVS200
input: SR <CR>
sr <CR> READY <CR/LF>
READY <CR/LF>
Command LR
command function
LR <level reference> reference level query
The command LR reads the actual set reference level in the "∆
∆∆
∆Level" mode.
Example: command from the controller response of the VOR/ILS Analyzer EVS200
query: LR <CR>
lr <CR> e.g. -48.1dBm <CR/LF>
e.g. -48.1dBm <CR/LF>
Command LD
command function
LR <level delta> ∆
∆∆
∆-Level query
The command LD reads the actual ∆
∆∆
∆-Level in the "∆
∆∆
∆Level" mode.
Example: command from the controller response of the VOR/ILS Analyzer EVS200
query: LD <CR>
ld <CR> e.g. -000.0dBm <CR/LF>
e.g. -000.0dBm <CR/LF>