VOR/ILS Analyzer EVS200

Chapter 4: Interfaces

External AF input

labeling

figure

 

description

 

 

 

 

 

AF EXT.

 

input level:

 

1 to 2 Vrms / 50 Ω

 

 

frequency range:

30 Hz to 10 kHz

 

 

 

 

 

RS-232-Interface

 

labeling

 

figure

 

description

 

 

 

 

 

 

 

 

 

standard RS-232-Interface

 

RS232/DDE

 

 

COM parameter:

N81

 

 

 

 

baud rate:

 

1200, 2400,

 

 

 

 

 

 

4800, 9600,

 

 

 

 

 

 

19200 adjustable in

 

 

 

 

 

 

the setup

 

 

 

 

 

 

 

External VDC connection

 

 

 

 

 

 

 

 

 

labeling

 

figure

 

description

 

 

 

 

 

 

 

 

INPUT: 9-15 VDC

 

 

DC connection:

 

12 VDC / 30 W

 

 

 

tolerance max.

 

9 to 15 VDC

 

 

 

 

 

 

 

Mains connection

 

labeling

figure

description

 

 

 

 

 

 

INPUT: 85-250 V/

 

mains connection:

87 to 265 VAC

 

47-63Hz

 

 

47 to 63 Hz

 

F1/F2: IEC127-

 

 

 

 

T800H/250V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0796.1800.02

E-8