VOR/ILS Analyzer EVS200

Chapter 6: Technical Specification

Glideslope mode

 

Measurement error at

≤ ±0.0008 DDM

30 to 50% modulation

 

 

±0.1% of reading

Resolution (LOC / GS)

0.0001 DDM

DSP out

 

0.0 ±25%

Localizer:

Range 1

 

 

0 ±0.25 DDM

 

Range 2

0.0 ±2.5%

 

 

0 ±0.025 DDM

 

Range 3

0.0 ±2.58%

 

 

0.0 ±0.0258 DDM

 

Range 4

0.0 ±50%

 

 

0.0 ±0.5 DDM

Glideslope:

Range 1

0.0 ±50%

 

 

0.0 ±0.5 DDM

 

Range 2

0.0 ±5%

 

 

0.0 ±0.05 DDM

 

Range 3

8.75 ±5%

 

 

0.0875 ±0.05 DDM

 

Range 4

17.5 +5%

 

 

0.175 +0.05 DDM

SDM measurement

 

SDM 10 to 80%

accuracy 1% absolute

Resolution

................................

0.0001 SDM

VOR signal analysis

Bearing

±0.1°

Accuracy

Resolution

0.05° / 0.01° (Setup)

AM modulation depth

 

30 Hz and 9,96 kHz

1%

Accuracy

Resolution

0.1%

FM deviation

0.5%, ±0.1 Hz

Accuracy

Resolution

0.1 Hz

RS-232-Interface

8N1, adjustable baud rate

 

1200, 2400, 4800, 9600, 19200

0796.1800.02

E-8

57

Page 66
Image 66
Procom EVS200 user manual VOR signal analysis