![](/images/new-backgrounds/1189420/18942085x1.webp)
VOR/ILS Analyzer EVS200
|
| Chapter 3: Operation | |
Command VER |
|
|
|
|
| ||
command | function |
| |
VER <Version> | query of version number and date of the |
| |
| EVS200 firmware |
| |
|
|
|
|
The command VER initializes the display of the software version number and its issue date.
Example: |
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 |
query: | VER <CR> | EVS200 - VERSION < No. > from < Date > |
| ver <CR> | |
| Copyright (C) Rohde & Schwarz Werk Köln | |
|
| |
|
| <CR/LF> |
Command ML
command | function |
ML | Δ level mode setting |
|
|
The command ML enables a switching over to the "Δ level" mode.
Exampel: |
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 |
input: | ML <CR> | READY <CR/LF> |
| ml <CR> | READY <CR/LF> |
Command MV
command | function |
MV | VOR mode setting |
|
|
The command MV enables a switching over to the "VOR“ mode.
Example: |
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 |
input: | MV <CR> | READY <CR/LF> |
| mv <CR> | READY <CR/LF> |
0796.1800.02 | 34 |