VOR/ILS Analyzer EVS200
|
| Chapter 3: Operation | |
Command AM9 |
|
|
|
|
| ||
command | function |
| |
AM9 | query |
| |
|
|
|
|
The command AM9 reads the actual
Prediction for reading out the data of the corresponding mode (VOR/ILS) is the switching over to display2.
Example: |
|
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 | |
query: | AM9 <CR> | e.g. | 09.6% <CR/LF> |
| am9 <CR> | e.g. | 09.6% <CR/LF> |
Command FA2
command | function |
FA2 <Fast measuring on> | Activating the Fast measurement mode |
|
|
The command FA2 switches on the fast measurement mode. The command FA2 performs the con- tinuous measurement and output of the RF level, Bearing, AM30, AM9960,
The measurement values can be read in and output as a text file corresponding to the terminal pro- gram.
The baud rate must be set to 19200 baud in the Setup of the VOR/ILS Analyzer EVS200.
It must be attended the acceptance of the data transfering rate by the terminal pro- gram.
The measurement can be stopped through the command FA0 (refer to Command FA0).
Example: | command from the controller | response of the VOR/ILS Analyzer EVS200 | |
| |||
input: | FA2 <CR> | output form: (RF level <CR >, Bearing <CR >, | |
| fa2 <CR> | AM30 <CR >, AM 9960 <CR >), | |
| With the command FA2 the echo | ||
| mode is automatically switched | ||
| OFF. | RF level: | |
|
| ||
|
| example: | |
|
|
| 122 <CR > (12.2dBm) |
|
| Modulation depth: | |
|
| example: | 304 <CR > (30.4 %) |
|
|
| 004 <CR > (0.4 %) |
|
|
| |
|
| example: 4800<CR > (480,0Hz) | |
|
|
| 0004 <CR > (0.4 Hz) |
|
|
| |
|
| example: | 160<CR > (16,0) |
0796.1800.02 | 47 |