In the following table all possible parameters are listed and its functions are described. Furthermore all possible setting values per parameter are shown. Next a sequence chart of the operating instructions in the SETUP mode is following.

Changes in the SETUP can be saved

with the softkey "SAVE".

 

parameter

description

 

setting value

 

 

 

 

 

RS232 BAUDRATE

baud rate setting

1200, 2400, 4800,

 

 

 

9600, 19200

 

VOR ANGLE-RESOLUTION

BEARING-angle resolution

0,01° / 0,05°

 

DDM/SDM AVG-FACTOR

factor for determining the number of

1, 2, 4, 8, 16, 32, 64

 

 

measurements which form the arithmeti-

 

 

 

 

cal average

 

 

 

DDM Y / t-RANGE [LOC]

XY value scaling in localizer mode at

RNG.1 to RNG.4

 

 

DSP-OUT (refer to page 10 DSP output)

 

 

 

DDM Y / t-RANGE [GS]

XY value scaling in glideslope mode at

RNG.1 to RNG.4

 

 

DSP-OUT (refer to page 10)

 

 

 

AF-INPUT-SOURCE

AF selection for valuation

INT = internal AF

 

 

 

EXT = external AF

 

 

 

via AF-EXT-input

 

STARTUP mode

startup mode setting at switching on the

VOR

(VOR mode)

 

 

unit

ILS

(ILS mode)

 

 

 

BCN

(Beacon mode)

 

 

 

SPEC

(Spectrum mode)

 

 

 

LEVEL (Δ level mode)

 

SQUELCH

on/off switching squelch

ON / OFF

 

 

 

 

 

setting valid for:

-Δ level mode

-ILS mode

-VOR mode

When the setting is "ON" an automatical quiet tuning is performed as soon as the threshold level < the receiver level is.

When setting is "OFF" no quiet tuning will be performed.

DISPLAY ILLUM

display brightness setting

OFF 1 to 6 ￿ MAX

DDM/SDM DIMENSIONS

value of DDM/SDM indication

μA / % / 1

 

 

(1= value without dimension)

DISPLAY-INTERVALL

indication interval time

1 to 8

 

setting is only valid for display indi-

 

cation.

 

 

1 to

8

 

approx. 0.4 s to approx. 1.8 s

TUNING-STEP

tuning step rate setting

5 / 25 / 50 / 100 (kHz)

0796.1800.02