VOR/ILS Analyzer EVS200

Chapter 3: Operation

VOR-Mode

Command BE

command

funcion

BE <Bearing Angle>

bearing angle query

 

 

The command BE reads the actual bearing angle (indicated in degree) in the VOR mode.

Example:

 

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

BE <CR>

e.g.

299.97DEG <CR/LF>

 

be <CR>

e.g.

299.97DEG <CR/LF>

Command AM0

command

function

 

AM0

<AM-modulation depth (30 Hz)>

query of AM-modulation depth (30 Hz)

 

The command AM0 reads the actual AM-modulation depth (30 Hz) in the VOR mode.

Example:

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM0 <CR>

e.g.

30.1% <CR/LF>

 

am0 <CR>

e.g.

30.1% <CR/LF>

Command AM1

command

function

AM1 <AM-modulation depth (9960 Hz)>

query of AM-modulation depth (9960 Hz)

 

 

The command AM1 reads the actual AM-modulation depth (9960 Hz) in the VOR mode.

Example:

 

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM1 <CR>

e.g.

30.1% <CR/LF>

 

am1 <CR>

e.g.

30.1% <CR/LF>

0796.1800.02

E-8

44

Page 53
Image 53