VOR/ILS Analyzer EVS200
Chapter 2: Preparation for Operation
Connection of Signal/Control Inputs/Outputs
Antenna connection
Via the RF INPUT at the frontside the VOR/ILS Analyzer EVS200 can be connected with a receiver antenna which agrees to frequency range.
As an option a RF input at the unit’s rear side is possible.
AF OUT
Via the AF OUT at the frontside the demodulated AF signal will be output.
AF signal  | bandwidth:  | 300 Hz to 4 kHz  | 
  | output level:  | approx.: 200 mVrms / 50 Ω / by 50% AM part  | 
e.g. VOR/ILS Analyzer =oscilloscope
RS-232-Interface 
Via the 
0796.1800.02  | 9  |