Gefen EXT-IP-2-RS2322 user manual Default Settings, RS-232 Settings

Page 80

Appendix

Default Settings

The following table lists the default setting of the IP to 2 x RS-232 Converter, as displayed under the built-in Web interface.

 

RS-232

 

 

 

 

RS-232 Settings

 

 

 

Select RS-232 Port

 

1

Description

 

None

RS-232 Mode

 

TCP Bridge

Baud Rate

 

19200

Data Bits

 

8

Parity

 

None

Stop Bits

 

1

Bridging Settings

 

 

 

Line Delay (ms)

 

0

Force Send (ms)

 

30

Force Send (bytes)

 

100

Add Delimiters to data sent

 

Disabled

Use Start Delimiter

 

Disabled

Start Delimiter Value

 

0

Use End Delimiter

 

Disabled

End Delimiter Value

 

0

TCP Port

 

49200

UDP Local Port

 

50200

UDP Echo

 

 

 

Destination IP

 

192.168.1.180

Destination Port

 

50000

UDP Echo

 

Disabled

page 70

Image 80 Contents
IP to RS-232 Important Safety Instructions Warranty Information Contacting Gefen Technical Support Operating Notes Web sitePacking List Features and Packing ListFeatures Vii Table of Contents Page Page Getting Started IP to 2xRS-232 Converter IntroductionIntroduction Connection Instructions InstallationSample Wiring Diagram Page Page Advanced Operation RS-232 and IP Configuration Configuration using the Gefen Discovery ToolConfiguration using RS-232 Diagram 2.1 Configuration using a null-modem cableInformation Commands Commands #help ExampleAdvanced Operation #setadddelim #setdevicedescr #setenddel #setgateway #sethttpport #setipadd #setnetmask #setsendbytecnt #setsendtimeout #setserialdescr #setserialmode #setserialparams Baud Rate = 19200 Bps Line Delay = 1000 ms #setstartdel #settcpbrport #settcptermport #settelnetpass #setudpbrport #setudpechobr #setudpport #setudpremotebr #setudprip #setudprport #showdelprms #showdevicedescr #showipconfig #showme #showserialdescr #showserialmode #showserialparams #showtelnetpass #showverdata #systemwidereset Param1 Value#usediscovery #usetcpaccess #usetcptermpass #useudpaccess #useudpecho Help Using the built-in Web InterfaceWeb Interface RS-232 Mode RS-232Select RS-232 Port DescriptionBaud Rate Data BitsParity Stop BitsForce Send bytes Line Delay msForce Send ms Add Delimiters to data sent Use Start DelimiterStart Delimiter Value Use End DelimiterUDP Local Port End Delimiter ValueTCP Port Set Defaults Destination IPDestination Port UDP EchoNetwork tab MAC AddressMode IP AddressGateway Http PortEnable TCP Access Require Password on ConnectOld Password User NameTerminal Port New PasswordConfirm Password UDP Port Enable UDP AccessEnable UDP Echo Destination UDP Port Enable DiscoveryDestination UDP IP Address Download Download Current Configuration Browse... Restore ConfigurationRestore System tab Browse... Firmware Update Update Factory Reset ResetPage Appendix Default Settings RS-232 SettingsIP Settings NetworkSpecifications Connectors, Indicators, and Controls RS-232Page Nordhoff St., Chatsworth CA