GE IC3645SR4U404N2, IC3645SP4U400N3 Controller motor current sensor, Input too low during running

Page 35

DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 35

TRACTION

DESCRIPTION OF STATUS

STATUS CODE

 

-57

Controller “motor current sensor”

input too low during running.

MEMORY RECALL

CORRECTIVE ACTIONS

YES

 

 

SYMPTOM

Circuits valid

Control will not operate.

 

for

POSSIBLE CAUSE

Traction

Defective control.

Replace controller unit.

Controller

 

 

 

CAUSE OF STATUS INDICATION

This status code will be displayed when the voltage input from the current sensor is too low during running.

TROUBLE-SHOOTING DIAGRAM

 

 

 

 

BRAKE SW.

 

 

FU5

P2 KEY SWITCH P1

SEATSW.

STARTSW.

FOR.SW.

REV. SW.

FU7

 

 

SP

 

TO

P5

 

 

 

 

 

 

L

 

 

 

 

FU6

ACCESSORIES

P4

 

 

 

 

P3

 

 

 

 

 

PY7

 

 

 

 

P4

 

 

PY12 P18

P17 P1 P2

P6

P3

P5

 

PY10

 

OSCILLATOR CARD

P7

P10 P9 P12 P8

 

PY11

 

LEFT CONTROL

 

 

 

LINE FU1

 

 

 

 

 

 

 

 

 

 

 

 

 

STEER

FU2

 

 

 

 

 

 

ANGLE

 

 

 

 

ACC POT

POT

 

 

 

 

 

 

+

FU4

 

 

 

 

 

 

 

BDI INTERRUPT

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

POS

A1

F1

FIELD

ARMATURE

NEG

A2

F2

FIELD

ARMATURE

-

 

 

POWER

 

 

 

 

 

 

POS

A1

F1

 

 

 

SP

CONNECTIONS

 

 

POWER

 

 

 

 

LEFT CONTROL

 

 

CONNECTIONS

 

 

 

 

NEG

A2

F2

 

 

RIGHT CONTROL

 

 

P

SP

 

 

 

 

 

 

 

 

 

 

TRACTION

DESCRIPTION OF STATUS

STATUS CODE

 

-64

The line driver input (P2-17) is less

than 12% of battery volts

MEMORY RECALL

CORRECTIVE ACTIONS

NO

 

 

SYMPTOM

Circuits valid

Control will not operate.

 

for

POSSIBLE CAUSE

Traction

-Open wire connection to Pin 17

- Shorted line Driver transistor

Controller

Defective control.

 

 

Replace controller unit.

 

 

CAUSE OF STATUS INDICATION

This status code will be displayed when the control detects that the line driver input (P2-17) is less than 12% battery volts when the key switch is turned on.

TROUBLE-SHOOTING DIAGRAM

 

 

 

 

BRAKE SW.

 

 

FU5

P2 KEY SWITCH P1

SEATSW.

STARTSW.

FOR.SW.

REV. SW.

FU7

 

 

SP

 

TO

P5

 

 

 

 

 

 

L

 

 

 

 

FU6

ACCESSORIES

P4

 

 

 

 

P3

 

 

 

 

 

PY7

 

 

 

 

P4

 

 

PY12 P18

P17 P1 P2

P6

P3

P5

 

PY10

 

OSCILLATOR CARD

P7

P10 P9 P12 P8

 

PY11

 

LEFT CONTROL

 

 

 

LINE FU1

 

 

 

 

 

 

 

 

 

 

 

 

 

STEER

FU2

 

 

 

 

 

 

ANGLE

 

 

 

 

ACC POT

POT

 

 

 

 

 

 

+

FU4

 

 

 

 

 

 

 

BDI INTERRUPT

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

POS

A1

F1

FIELD

ARMATURE

NEG

A2

F2

FIELD

ARMATURE

-

 

 

POWER

 

 

 

 

 

 

POS

A1

F1

 

 

 

SP

CONNECTIONS

 

 

POWER

 

 

 

 

LEFT CONTROL

 

 

CONNECTIONS

 

 

 

 

NEG

A2

F2

 

 

RIGHT CONTROL

 

 

P

SP

 

 

 

 

 

 

 

 

 

 

January 2000

Image 35
Contents Installation and Operation Table of Contents 57-62 20-4041-45 46-52Motor Characteristics Basic Operation and FeaturesSlows with the increase of current in the field More Features with Fewer ComponentsSolid-State Reversing Flexible System Application3.c Pedal Position Plug Braking 1.b Creep Speed1.c Control Acceleration 2 Current Limit5 Ramp Operation 5a Ramp Start 6 Steer Pump Contactor Time Delay4.b Speed Limits 4.c Proportional Operation for Dual Motor Vehicles2 Accelerator Volts Hold Off Diagnostics 1 Systems Diagnostics7 On-Board Coil Drivers & Internal Coil Suppression System Protective Override 1 Static Return to Off SRO4.a Internal Resistance Compensation 3.a Maintenance Alert & Speed Limit4 Battery Discharge Indication BDI 3 Hourmeter ReadingsBasic Operation and Features Argument Outline DRAWINGS, Elementary Drawings and INPUTS/OUTPUTSPart Number Outline SX-3 and SR-3 Package Size Drawings and INPUTS/OUTPUTS Section DRAWINGS, Elementary Drawings and INPUTS/OUTPUTS ControlPIN Connections to Main Plug 23 PIN and Y Plug 12 PINDiagnostic Status Codes Cable Spacing Guidelines High-Level Signals Level HMedium-Power Signals Level MP 2.d. High Power Signals Level HP328A1777G1 CleanerReconnect plugs General Troubleshooting Instructions Status Code No seat switch or deadman switchTraction Control Codes TractionDescription of Status Cause of Status Indication Reverse directional switch is closed onDirection selected Start switch fails to closeAccelerator depressed with no KEY Negative Same time Directional switches are closed atBoth the forward and reverse Initial key switch closure Start switch closed on power up afterDischarged battery Forward direction Motor field current is high on start upReverse direction Motor field current is too high during Volts DC Power supply is less than 10 voltsRun mode Traction Controller Slave/auxiliary control Open thermal protector TP or Transistor over temperatureProperly Motor armature offset voltage is tooLow Armature transistor did not turn offLook Ahead test for A2 volts less Than 12% of battery voltsArmature transistor did not turn on Contactor closes Motor field current is too low duringCapacitor volts are low before the line Line driver input P2-17 is less Controller motor current sensorInput too low during running Description Armature transistor limit Armature current exceedsVerify connection between the master control P21 Traction Status Code Symptom TMM Status Codes TemperatureSteer Plug P5 pump is shorted to positive Plug P8 pump is shorted to positive Corrective Actions TROUBLE-SHOOTING Diagram YES Possible Cause SymptomPump Open thermal protector TP1 or Transistor is over temperatureControl range No power to pump motorPump Controller motor current Sensor input is missingWith no pump contactor, control Power Transistor Q1 did notPower Transistor Q1 did not turn on Turn off properlyContactor closes Capacitor volts are low after the lineCheck Controller motor currentSensor input voltage polarity Voltage at capacitor 1C is less than Volts Battery voltage is less thanTMM7A TMM7A Outline Drawings 3 TMM Pump Control ConnectionsSTART-UP Display Sequence Adjustable FeaturesRemarks Accessing Stored Status Codes With GE HandsetAction Function Function 10 Field Current for Regen Function 16 Stall Trip Point with % ON-TIME Push Battery VoltsBattery volts Set units Internal Resistance CompensationFunction 26 Base Ratio Function 19 Maintenance Code Tens and Units Hours SETFunction 25 Monitor Function 28 Stored Status Code Count Pointer Push Function 49 Mode 1 Field Weakening Start PushFunction 51 Mode 1 MAX Armature % on Function 59 Mode 3 MAX Armature % on Function 52 Mode 2 Armature Controlled AccelerationFunction 55 Mode 2 MAX Armature % on Function 57 Mode 3 Field Weakening StartField Current Summary of Current Limit AdjustmentsFunction 16 Speed / Torque Compensation Function Current LimitFunction 14 not Applicable Function 50 Mode 1 Speed Limit 3 SL3 Speed / Torque Compensation Table Voltage SettingFunction 48 Mode 1 Controlled Acceleration Push Function 49 Mode 1 Speed Limit 2 SL2 PushFunction 59 not Applicable Function 53 Mode 2 Speed Limit 2 SL2Function 54 Mode 2 Speed Limit 3 SL3 Function 55 not ApplicableConnections Dash DisplaysApplication Standard Dash DisplaysOutline Drawings Start-Up Display SequenceOperation Turn Angle Potentiometer InstallationSetup Degree Potentiometer for Steer Angle Input Degree Potentiometer Left Right Restrictions Function RS-232 Memory MAP TablesTraction Control Reset to Zero Only HoursThou/Hun Reset to Zero Only Stored Status Code #5Reset to Zero Only Stored Status Code #6 Reset to Zero Only HoursTens/OnesNone Reset to Zero Only Stored Status Code #16Reset to Zero Only Dash Display CA-1 Dash Display FWS-1 None Dash Display Ratio2-1