GE IC3645SR4U404N2, IC3645SP4U400N3 Function 28 Stored Status Code Count Pointer Push

Page 61

ADJUSTABLE FEATURES

SX TRANSISTOR CONTROLS

Page 61

The ratio value (VAL) is the set value divided by 10 and rounded to the whole number.

Example: Setting of 45 = 45/10 = 4.5 = 4 VAL

IFIELD = VAL ( IMOTOR x 0.029 )

FUNCTION 28 STORED STATUS CODE COUNT POINTER ( Push CONT 13)

This register contains the location of the last stored status code recorded of the 16 stored status codes. These stored status codes have caused a PMT controller shutdown and/or disruption of normal vehicle operation.

To determine which stored status code was the last one recorded, read the number stored in Function 28. Using the Memory Map for your logic card, match the "stored status code pointer number" [the number shown in (bold italics) in the HS (Handset) number column] on the memory map, with the number obtained from Function 28. This will be the last stored status code recorded.

Note: When scrolling through the stored status code register, the register always starts at status code 1 and scrolls to status code 16. Instructions for scrolling the register are in section 6.3.2 of this instruction booklet.

The following functions have function numbers larger than the numbers on the Handset keyboard. To access these functions. Push the CONT key and the number shown in the following instructions at the same time.

THE SEAT SWITCH MUST BE CLOSED.

FUNCTION 48 MODE 1 (TURTLE) - ARMATURE CONTROLLED ACCELERATION ( Push CONT 1)

This function allows for the adjustment of the rate of time it takes for the control to accelerate to 100% applied battery voltage to the motor on hard acceleration.

Range

0.025 to 6.3 seconds

Set

0 to 255

Resolution

0.025 seconds per set unit

Example:

Setting of 20 = 0.5 seconds

This C/A takes effect when the Mode 1 settings are called for by the interactive Dash Display.

FUNCTION 49 MODE 1 FIELD WEAKENING START ( Push CONT 2)

This function allows for setting the armature current at which minimum field current will achieved .

Range

0 to 414 Amps

Setting

0 to 255

Resolution

1.625 per set unit

Example: Setting of 20 = 32.5 amps

I M FWS = VAL x 1.625

This FIELD WEAKENING START takes effect when the Mode 1 settings are called for by the interactive Dash Display.

FUNCTION 50 MODE 1 FW RATIO ( Push CONT 3 )

This function sets the ratio between armature and field current when transitioning from minimum field to maximum field current. The setting represents the quantity of field current changed for each 1 amp of armature current changed.

Max Fld Ref

Set

Resolution Per Unit Value

40

0 to 10

0.029 amps

The ratio value (VAL) is the set value divided by 10 and rounded to the lowest whole number.

Example : Setting of 45 = 45/10 = 4.5 = 4 VAL.

IFIELD = VAL ( IMOTOR X .029 )

This FW RATIO takes effect when the Mode 1 settings are called for by the interactive Dash Display.

FUNCTION 51 MODE 1 MAX ARMATURE % ON

( Push CONT 4)

This function allows for the adjustment of the speed limit (maximum battery volts to the motor) when the SL1 limit switch input signal is received by the control card. The SL1 limit switch is a normally closed switch connected to battery negative; the switch opening enables speed limit.

Range

100% to 0% battery volts

Set

51 to 180

Resolution

0.78 % per set unit

Example

Setting of 71 = 84.4 % battery

 

volts

This MAX ARMATURE % ON takes effect when the Mode 1 settings are called for by the interactive Dash Display.

January 2000

Image 61
Contents Installation and Operation Table of Contents 41-45 20-4046-52 57-62Motor Characteristics Basic Operation and FeaturesSolid-State Reversing More Features with Fewer ComponentsFlexible System Application Slows with the increase of current in the field1.c Control Acceleration 1.b Creep Speed2 Current Limit 3.c Pedal Position Plug Braking4.b Speed Limits 6 Steer Pump Contactor Time Delay4.c Proportional Operation for Dual Motor Vehicles 5 Ramp Operation 5a Ramp Start7 On-Board Coil Drivers & Internal Coil Suppression Diagnostics 1 Systems DiagnosticsSystem Protective Override 1 Static Return to Off SRO 2 Accelerator Volts Hold Off4 Battery Discharge Indication BDI 3.a Maintenance Alert & Speed Limit3 Hourmeter Readings 4.a Internal Resistance CompensationBasic Operation and Features Part Number Outline DRAWINGS, Elementary Drawings and INPUTS/OUTPUTSArgument Outline SX-3 and SR-3 Package Size Drawings and INPUTS/OUTPUTS Section DRAWINGS, Elementary Drawings and INPUTS/OUTPUTS ControlPIN Connections to Main Plug 23 PIN and Y Plug 12 PINDiagnostic Status Codes Medium-Power Signals Level MP High-Level Signals Level H2.d. High Power Signals Level HP Cable Spacing GuidelinesReconnect plugs Cleaner328A1777G1 General Troubleshooting Instructions Traction Control Codes No seat switch or deadman switchTraction Status CodeDescription of Status Cause of Status Indication Reverse directional switch is closed onAccelerator depressed with no Start switch fails to closeDirection selected KEY Negative Both the forward and reverse Directional switches are closed atSame time Initial key switch closure Start switch closed on power up afterDischarged battery Reverse direction Motor field current is high on start upForward direction Run mode Volts DC Power supply is less than 10 voltsMotor field current is too high during Traction Controller Slave/auxiliary control Open thermal protector TP or Transistor over temperatureLow Motor armature offset voltage is tooArmature transistor did not turn off ProperlyArmature transistor did not turn on Than 12% of battery voltsLook Ahead test for A2 volts less Capacitor volts are low before the line Motor field current is too low duringContactor closes Input too low during running Controller motor current sensorLine driver input P2-17 is less Description Armature transistor limit Armature current exceedsVerify connection between the master control P21 Traction Status Code Symptom TMM Status Codes TemperatureSteer Plug P5 pump is shorted to positive Plug P8 pump is shorted to positive Corrective Actions TROUBLE-SHOOTING Diagram YES Pump SymptomPossible Cause Open thermal protector TP1 or Transistor is over temperaturePump Controller motor current No power to pump motorSensor input is missing Control rangePower Transistor Q1 did not turn on Power Transistor Q1 did notTurn off properly With no pump contactor, controlContactor closes Capacitor volts are low after the lineSensor input voltage polarity Controller motor currentCheck Voltage at capacitor 1C is less than Volts Battery voltage is less thanTMM7A TMM7A Outline Drawings 3 TMM Pump Control ConnectionsSTART-UP Display Sequence Adjustable FeaturesAction Accessing Stored Status Codes With GE HandsetRemarks Function Function 10 Field Current for Regen Battery volts Set units Battery VoltsInternal Resistance Compensation Function 16 Stall Trip Point with % ON-TIME PushFunction 25 Monitor Function 19 Maintenance Code Tens and Units Hours SETFunction 26 Base Ratio Function 51 Mode 1 MAX Armature % on Function 49 Mode 1 Field Weakening Start PushFunction 28 Stored Status Code Count Pointer Push Function 55 Mode 2 MAX Armature % on Function 52 Mode 2 Armature Controlled AccelerationFunction 57 Mode 3 Field Weakening Start Function 59 Mode 3 MAX Armature % onField Current Summary of Current Limit AdjustmentsFunction 14 not Applicable Function Current LimitFunction 16 Speed / Torque Compensation Function 48 Mode 1 Controlled Acceleration Push Speed / Torque Compensation Table Voltage SettingFunction 49 Mode 1 Speed Limit 2 SL2 Push Function 50 Mode 1 Speed Limit 3 SL3Function 54 Mode 2 Speed Limit 3 SL3 Function 53 Mode 2 Speed Limit 2 SL2Function 55 not Applicable Function 59 not ApplicableApplication Dash DisplaysStandard Dash Displays ConnectionsOutline Drawings Start-Up Display SequenceSetup Turn Angle Potentiometer InstallationOperation Degree Potentiometer for Steer Angle Input Degree Potentiometer Left Right Traction Control RS-232 Memory MAP TablesRestrictions Function Reset to Zero Only Stored Status Code #6 Reset to Zero Only Stored Status Code #5Reset to Zero Only HoursTens/Ones Reset to Zero Only HoursThou/HunReset to Zero Only Dash Display CA-1 Dash Display FWS-1 Reset to Zero Only Stored Status Code #16None Dash Display Ratio2-1 None