GE IC3645SP4U400N3, IC3645SR4U404N2 operation manual Description

Page 36

DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 36

TRACTION

DESCRIPTION OF

STATUS CODE

STATUS

-65

The line coil current is too high

during the run mode

MEMORY RECALL

CORRECTIVE ACTIONS

YES

 

 

SYMPTOM

Circuits valid

Control will not operate.

 

for

POSSIBLE CAUSE

Traction

- Shorted line contactor coil

Controller

- Short between wires connected to

 

line coil (wires #10 and 24)

 

If line coil resistance is correct:

 

Defective control.

 

Replace controller unit.

 

 

CAUSE OF STATUS INDICATION

This status code will be displayed when the current limit in the line coil is exceeded during the run mode. The line contactor will drop out and the key switch will have to be recycled to reset the control.

TROUBLE-SHOOTING DIAGRAM

 

 

 

 

BRAKE SW.

 

 

FU5

P2 KEY SWITCH P1

SEATSW.

STARTSW.

FOR.SW.

REV. SW.

FU7

 

 

SP

 

TO

P5

 

 

 

 

 

 

L

 

 

 

 

FU6

ACCESSORIES

P4

 

 

 

 

P3

 

 

 

 

 

PY7

 

 

 

 

P4

 

 

PY12 P18

P17 P1 P2

P6

P3

P5

 

PY10

 

OSCILLATOR CARD

P7

P10 P9 P12 P8

 

PY11

 

LEFT CONTROL

 

 

 

LINE FU1

 

 

 

 

 

 

 

 

 

 

 

 

 

STEER

FU2

 

 

 

 

 

 

ANGLE

 

 

 

 

ACC POT

POT

 

 

 

 

 

 

+

FU4

 

 

 

 

 

 

 

BDI INTERRUPT

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

POS

A1

F1

FIELD

ARMATURE

NEG

A2

F2

FIELD

ARMATURE

-

 

 

POWER

 

 

 

 

 

 

POS

A1

F1

 

 

 

SP

CONNECTIONS

 

 

POWER

 

 

 

 

LEFT CONTROL

 

 

CONNECTIONS

 

 

 

 

NEG

A2

F2

 

 

RIGHT CONTROL

 

 

P

SP

 

 

 

 

 

 

 

 

 

 

TRACTION

 

DESCRIPTION OF

STATUS CODE

 

STATUS

-66

The field current exceeds the

current limit of the field transistor.

MEMORY RECALL

CORRECTIVE ACTIONS

YES

 

 

 

SYMPTOM

Circuits valid

Control will not operate

Line contactor opens

for

POSSIBLE CAUSE

Traction

Shorted field F1 to F2

F1 or F2 terminals shorted to battery

Controller

 

positive (B+)

 

F1 or F2 terminals shorted to battery

 

 

negative (B-)

 

 

 

CAUSE OF STATUS INDICATION

This status code will be displayed when the field transistor exceeds its specific current limit. The line contactor will drop out and the key switch will have to be recycled to restart the control.

TROUBLE-SHOOTING DIAGRAM

 

 

 

 

BRAKE SW.

 

 

FU5

P2 KEY SWITCH P1

SEATSW.

STARTSW.

FOR.SW.

REV. SW.

FU7

 

 

SP

 

TO

P5

 

 

 

 

 

 

L

 

 

 

 

FU6

ACCESSORIES

P4

 

 

 

 

P3

 

 

 

 

 

PY7

 

 

 

 

P4

 

 

PY12 P18

P17 P1 P2

P6

P3

P5

 

PY10

 

OSCILLATOR CARD

P7

P10 P9 P12 P8

 

PY11

 

LEFT CONTROL

 

 

 

LINE FU1

 

 

 

 

 

 

 

 

 

 

 

 

 

STEER

FU2

 

 

 

 

 

 

ANGLE

 

 

 

 

ACC POT

POT

 

 

 

 

 

 

+

FU4

 

 

 

 

 

 

 

BDI INTERRUPT

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

POS

A1

F1

FIELD

ARMATURE

NEG

A2

F2

FIELD

ARMATURE

-

 

 

POWER

 

 

 

 

 

 

POS

A1

F1

 

 

 

SP

CONNECTIONS

 

 

POWER

 

 

 

 

LEFT CONTROL

 

 

CONNECTIONS

 

 

 

 

NEG

A2

F2

 

 

RIGHT CONTROL

 

 

P

SP

 

 

 

 

 

 

 

 

 

 

January 2000

Image 36
Contents Installation and Operation Table of Contents 20-40 41-4546-52 57-62Basic Operation and Features Motor CharacteristicsMore Features with Fewer Components Solid-State ReversingFlexible System Application Slows with the increase of current in the field1.b Creep Speed 1.c Control Acceleration2 Current Limit 3.c Pedal Position Plug Braking6 Steer Pump Contactor Time Delay 4.b Speed Limits4.c Proportional Operation for Dual Motor Vehicles 5 Ramp Operation 5a Ramp StartDiagnostics 1 Systems Diagnostics 7 On-Board Coil Drivers & Internal Coil SuppressionSystem Protective Override 1 Static Return to Off SRO 2 Accelerator Volts Hold Off3.a Maintenance Alert & Speed Limit 4 Battery Discharge Indication BDI3 Hourmeter Readings 4.a Internal Resistance CompensationBasic Operation and Features Outline DRAWINGS, Elementary Drawings and INPUTS/OUTPUTS Part NumberArgument Outline SX-3 and SR-3 Package Size Drawings and INPUTS/OUTPUTS DRAWINGS, Elementary Drawings and INPUTS/OUTPUTS Control SectionConnections to Main Plug 23 PIN and Y Plug 12 PIN PINDiagnostic Status Codes High-Level Signals Level H Medium-Power Signals Level MP2.d. High Power Signals Level HP Cable Spacing GuidelinesCleaner Reconnect plugs328A1777G1 General Troubleshooting Instructions No seat switch or deadman switch Traction Control CodesTraction Status CodeReverse directional switch is closed on Description of Status Cause of Status IndicationStart switch fails to close Accelerator depressed with noDirection selected KEY Negative Directional switches are closed at Both the forward and reverseSame time Start switch closed on power up after Initial key switch closureDischarged battery Motor field current is high on start up Reverse directionForward direction Volts DC Power supply is less than 10 volts Run modeMotor field current is too high during Traction Controller Slave/auxiliary control Transistor over temperature Open thermal protector TP orMotor armature offset voltage is too LowArmature transistor did not turn off ProperlyThan 12% of battery volts Armature transistor did not turn onLook Ahead test for A2 volts less Motor field current is too low during Capacitor volts are low before the lineContactor closes Controller motor current sensor Input too low during runningLine driver input P2-17 is less Description Armature current exceeds Armature transistor limitVerify connection between the master control P21 Traction Status Code Symptom Temperature TMM Status CodesSteer Plug P5 pump is shorted to positive Plug P8 pump is shorted to positive Corrective Actions TROUBLE-SHOOTING Diagram YES Symptom PumpPossible Cause Transistor is over temperature Open thermal protector TP1 orNo power to pump motor Pump Controller motor currentSensor input is missing Control rangePower Transistor Q1 did not Power Transistor Q1 did not turn onTurn off properly With no pump contactor, controlCapacitor volts are low after the line Contactor closesController motor current Sensor input voltage polarityCheck Battery voltage is less than Voltage at capacitor 1C is less than VoltsTMM7A 3 TMM Pump Control Connections TMM7A Outline DrawingsAdjustable Features START-UP Display SequenceAccessing Stored Status Codes With GE Handset ActionRemarks Function Function 10 Field Current for Regen Battery Volts Battery volts Set unitsInternal Resistance Compensation Function 16 Stall Trip Point with % ON-TIME PushFunction 19 Maintenance Code Tens and Units Hours SET Function 25 MonitorFunction 26 Base Ratio Function 49 Mode 1 Field Weakening Start Push Function 51 Mode 1 MAX Armature % onFunction 28 Stored Status Code Count Pointer Push Function 52 Mode 2 Armature Controlled Acceleration Function 55 Mode 2 MAX Armature % onFunction 57 Mode 3 Field Weakening Start Function 59 Mode 3 MAX Armature % onSummary of Current Limit Adjustments Field CurrentFunction Current Limit Function 14 not ApplicableFunction 16 Speed / Torque Compensation Speed / Torque Compensation Table Voltage Setting Function 48 Mode 1 Controlled Acceleration PushFunction 49 Mode 1 Speed Limit 2 SL2 Push Function 50 Mode 1 Speed Limit 3 SL3Function 53 Mode 2 Speed Limit 2 SL2 Function 54 Mode 2 Speed Limit 3 SL3Function 55 not Applicable Function 59 not ApplicableDash Displays ApplicationStandard Dash Displays ConnectionsStart-Up Display Sequence Outline DrawingsTurn Angle Potentiometer Installation SetupOperation Degree Potentiometer for Steer Angle Input Degree Potentiometer Left Right RS-232 Memory MAP Tables Traction ControlRestrictions Function Reset to Zero Only Stored Status Code #5 Reset to Zero Only Stored Status Code #6Reset to Zero Only HoursTens/Ones Reset to Zero Only HoursThou/HunReset to Zero Only Stored Status Code #16 Reset to Zero Only Dash Display CA-1 Dash Display FWS-1None Dash Display Ratio2-1 None