GE IC3645SP4U400N3 Reset to Zero Only Stored Status Code #16, None Dash Display Ratio2-1, OEM Use

Page 74

 

RS-232 MEMORY MAP TABLES

 

 

 

 

SX TRANSISTOR CONTROL

 

 

Page 74

 

 

 

 

 

 

 

 

 

 

E2

Func No.

HS

Traction Control

Access By

Restrictions

 

 

 

 

No.

Function

 

 

 

 

90

91

 

Hours (Tens/Ones) 15

PC Only

Reset to Zero Only

 

 

 

 

 

 

 

 

 

 

91

92

 

Hours (Thou/Hun) 15

PC Only

Reset to Zero Only

 

 

92

93

(48)

Stored Status Code #16

PC Only

Reset to Zero Only

 

 

 

 

 

 

 

 

 

 

94

95

 

Hours (Tens/Ones) 16

PC Only

Reset to Zero Only

 

 

 

 

 

 

 

 

 

 

95

96

 

Hours (Thou/Hun) 16

PC Only

Reset to Zero Only

 

 

 

 

 

 

 

 

 

 

96

67

48

Dash Display CA-1

 

 

 

 

97

98

49

Dash Display FWS-1

HS or PC

None

 

 

 

 

 

 

 

 

 

 

98

99

50

Dash Display Ratio2-1

HS or PC

None

 

 

 

 

 

 

 

 

 

 

99

100

51

Dash Display Speed Limit 2 - 1

HS or PC

None

 

 

 

 

 

 

 

 

 

 

100

101

52

Dash Display CA-2

HS or PC

None

 

 

101

102

53

Dash Display FWS-2

HS or PC

None

 

 

 

 

 

 

 

 

 

 

102

103

54

Dash Display Ratio2-2

HS or PC

None

 

 

 

 

 

 

 

 

 

 

103

104

55

Dash Display Speed Limit 2 - 2

HS or PC

None

 

 

 

 

 

 

 

 

 

 

104

105

56

Dash Display CA-3

HS or PC

None

 

 

105

106

57

Dash Display FWS-3

HS or PC

None

 

 

 

 

 

 

 

 

 

 

106

107

58

Dash Display Ratio2-3

HS or PC

None

 

 

 

 

 

 

 

 

 

 

107

108

59

Dash Display Speed Limit 2 - 3

HS or PC

None

 

 

 

 

 

 

 

 

 

 

108

109

60

Dash Display CA-4

HS or PC

None

 

 

109

110

61

Dash Display FWS-4

HS or PC

None

 

 

 

 

 

 

 

 

 

 

110

111

62

Dash Display Ratio2-4

HS or PC

None

 

 

 

 

 

 

 

 

 

 

111

112

63

Dash Display Speed Limit 2 - 4

HS or PC

None

 

 

 

 

 

 

 

 

 

 

112

113

 

Secure HM (Tens/Ones)

PC Only

OEM Read Only

 

 

113

114

 

Secure HM (Thou/Hun)

PC Only

OEM Read Only

 

 

114

115

 

Secure Aux HM (Tens/Ones)

PC Only

OEM Read Only

 

 

 

 

 

 

 

 

 

 

115

116

 

Secure Aux HM (Thou/Hun)

PC Only

OEM Read Only

 

 

 

 

 

 

 

 

 

 

116

117

 

Reserved

PC Only

GE Future Use

 

 

 

 

 

 

 

 

 

 

117

118

 

Reserved

PC Only

GE Future Use

 

 

118

119

 

Reserved

PC Only

GE Future Use

 

 

 

 

 

 

 

 

 

 

119

120

 

Reserved

PC Only

GE Future Use

 

 

 

 

 

 

 

 

 

 

120

121

 

OEM Use

PC Only

None

 

 

 

 

 

 

 

 

 

 

121

122

 

OEM Use

PC Only

None

 

 

122

123

 

OEM Use

PC Only

None

 

 

 

 

 

 

 

 

 

 

123

124

 

OEM Use

PC Only

None

 

 

 

 

 

 

 

 

 

 

124

125

 

OEM Use

PC Only

None

 

 

 

 

 

 

 

 

 

 

125

126

 

OEM Use

PC Only

None

 

 

126

127

 

OEM Use

PC Only

None

 

 

 

 

 

 

 

 

 

 

127

128

 

OEM Use

PC Only

None

 

 

 

 

 

 

 

 

 

Numbers in (bold italics) are Stored Status Code pointers.

January 2000

Image 74
Contents Installation and Operation Table of Contents 46-52 20-4041-45 57-62Basic Operation and Features Motor CharacteristicsFlexible System Application More Features with Fewer ComponentsSolid-State Reversing Slows with the increase of current in the field2 Current Limit 1.b Creep Speed1.c Control Acceleration 3.c Pedal Position Plug Braking4.c Proportional Operation for Dual Motor Vehicles 6 Steer Pump Contactor Time Delay4.b Speed Limits 5 Ramp Operation 5a Ramp StartSystem Protective Override 1 Static Return to Off SRO Diagnostics 1 Systems Diagnostics7 On-Board Coil Drivers & Internal Coil Suppression 2 Accelerator Volts Hold Off3 Hourmeter Readings 3.a Maintenance Alert & Speed Limit4 Battery Discharge Indication BDI 4.a Internal Resistance CompensationBasic Operation and Features Argument Outline DRAWINGS, Elementary Drawings and INPUTS/OUTPUTSPart Number Outline SX-3 and SR-3 Package Size Drawings and INPUTS/OUTPUTS DRAWINGS, Elementary Drawings and INPUTS/OUTPUTS Control SectionConnections to Main Plug 23 PIN and Y Plug 12 PIN PINDiagnostic Status Codes 2.d. High Power Signals Level HP High-Level Signals Level HMedium-Power Signals Level MP Cable Spacing Guidelines328A1777G1 CleanerReconnect plugs General Troubleshooting Instructions Traction No seat switch or deadman switchTraction Control Codes Status CodeReverse directional switch is closed on Description of Status Cause of Status IndicationDirection selected Start switch fails to closeAccelerator depressed with no KEY Negative Same time Directional switches are closed atBoth the forward and reverse Start switch closed on power up after Initial key switch closureDischarged battery Forward direction Motor field current is high on start upReverse direction Motor field current is too high during Volts DC Power supply is less than 10 voltsRun mode Traction Controller Slave/auxiliary control Transistor over temperature Open thermal protector TP orArmature transistor did not turn off Motor armature offset voltage is tooLow ProperlyLook Ahead test for A2 volts less Than 12% of battery voltsArmature transistor did not turn on Contactor closes Motor field current is too low duringCapacitor volts are low before the line Line driver input P2-17 is less Controller motor current sensorInput too low during running Description Armature current exceeds Armature transistor limitVerify connection between the master control P21 Traction Status Code Symptom Temperature TMM Status CodesSteer Plug P5 pump is shorted to positive Plug P8 pump is shorted to positive Corrective Actions TROUBLE-SHOOTING Diagram YES Possible Cause SymptomPump Transistor is over temperature Open thermal protector TP1 orSensor input is missing No power to pump motorPump Controller motor current Control rangeTurn off properly Power Transistor Q1 did notPower Transistor Q1 did not turn on With no pump contactor, controlCapacitor volts are low after the line Contactor closesCheck Controller motor currentSensor input voltage polarity Battery voltage is less than Voltage at capacitor 1C is less than VoltsTMM7A 3 TMM Pump Control Connections TMM7A Outline DrawingsAdjustable Features START-UP Display SequenceRemarks Accessing Stored Status Codes With GE HandsetAction Function Function 10 Field Current for Regen Internal Resistance Compensation Battery VoltsBattery volts Set units Function 16 Stall Trip Point with % ON-TIME PushFunction 26 Base Ratio Function 19 Maintenance Code Tens and Units Hours SETFunction 25 Monitor Function 28 Stored Status Code Count Pointer Push Function 49 Mode 1 Field Weakening Start PushFunction 51 Mode 1 MAX Armature % on Function 57 Mode 3 Field Weakening Start Function 52 Mode 2 Armature Controlled AccelerationFunction 55 Mode 2 MAX Armature % on Function 59 Mode 3 MAX Armature % onSummary of Current Limit Adjustments Field CurrentFunction 16 Speed / Torque Compensation Function Current LimitFunction 14 not Applicable Function 49 Mode 1 Speed Limit 2 SL2 Push Speed / Torque Compensation Table Voltage SettingFunction 48 Mode 1 Controlled Acceleration Push Function 50 Mode 1 Speed Limit 3 SL3Function 55 not Applicable Function 53 Mode 2 Speed Limit 2 SL2Function 54 Mode 2 Speed Limit 3 SL3 Function 59 not ApplicableStandard Dash Displays Dash DisplaysApplication ConnectionsStart-Up Display Sequence Outline DrawingsOperation Turn Angle Potentiometer InstallationSetup Degree Potentiometer for Steer Angle Input Degree Potentiometer Left Right Restrictions Function RS-232 Memory MAP TablesTraction Control Reset to Zero Only HoursTens/Ones Reset to Zero Only Stored Status Code #5Reset to Zero Only Stored Status Code #6 Reset to Zero Only HoursThou/HunNone Dash Display Ratio2-1 Reset to Zero Only Stored Status Code #16Reset to Zero Only Dash Display CA-1 Dash Display FWS-1 None