Ducane 20529915 owner manual Portable Installation, Gas Leaks Checks

Page 9

CONNECTION Natural Gas Grills

Portable Installation

Limited portability can be afforded to the grill head when mounted on the portable cart. All grill heads mounted on this portable cart and cabinet model grills so equipped can be moved about 10 feet away from the main gas supply. Ducane recommends moving the grill at least two (2) feet from the gas supply and any combustible surfaces. After the gas supply has been run and checked for leaks in accordance to the assembly instructions, you are ready to grill. To connect the hose to the gas supply, pull back the outer fitting, insert the hose fitting all of the way, and release the outer fitting. This process will produce a gas joint.

Follow special storage instructions located in the Helpful Hints section of this manual for proper care of your grill and its gas hose.

Gas Leaks Checks

Before operating your grill, check carefully to be certain that all connections are tight and there are no gas leaks. Never use a match or flame for leak detection. Use soapy water or testing solution. Brush the solution on to connection points and look closely for bubbles indicating escaping gas. If leaks are detected, shut off the main gas supply valve and securely retighten connections, then repeat the leak test.

CAUTION: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (14” wc).

CAUTION: The appliance must be isolated from the gas sup- ply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (14” wc).

WARNING: Never use an open flame when testing for gas leaks! Use of an open flame may result in serious bodily injury or death, or in a fire or an explosion causing damage to property.

IMPORTANT

Installation must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or CAN/ CGA-B149.1; Natural Gas and Propane Installation Code.

IMPORTANT

When connecting or replacing any gas pipe or fittings, all joints must be sealed with leak-proof sealing compound approved for use with natural and propane gases. After making connections, check all joints for leaks using soapy water and a brush.

 

 

1

 

 

2

5

4

3

 

 

6

7

8

 

 

 

1

 

Natural Gas Regulator

 

 

 

2

 

Flare Union

 

 

 

3

 

Swivel Connection

4

 

Install covers when hose is disconnected.

 

 

 

5

 

Shut Off Valve

6Coat this pipe nipple with gas resistant pipe dope.

7

 

 

Socket

 

 

 

 

 

 

8

 

Male Connection

 

 

 

 

 

 

 

1

2

3

 

 

 

 

 

FLOW

 

 

 

 

 

 

 

 

 

 

FLOW

 

 

 

4

 

FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

Socket

 

 

 

 

 

 

2

 

 

Sleeve

 

 

 

 

 

 

3

 

 

Plug

 

 

 

 

 

4

Push plug until sleeve snapsf orward locking plug in socket. (This

 

turns on gas automatically.)

 

 

2

1

3

FLOW

FLOW

1

Socket

2

Sleeve

 

 

3

Push Sleeve Back

When properly assembled the plug cannot be removed without pushing the sleeve back. To disconnect, push sleeve back and pull out plug.

(This automatically shuts off gas.)

Image 9
Contents #20529915 Page Assembly, ENSAMBLAJE, Assemblage Important SafeguardsNeeded Assembly, ENSAMBLAJE, Assemblage Five-Year Limited Warranty Warranty, Garantía, garantieGarantía limitada de cinco años Safety InformationWhat is Natural Gas? AssemblyLocating Your Grill LevelingGas Leaks Checks Portable InstallationNormal Operation Plug in Accessory Power to Your GrillLighting Your Grill Preheating GrillMain Burner Snap Ignition Post-heating GrillMatch Lighting Your Grill Main Burners For Natural Gas Grills and System PropaneSide Burner Snap Ignition Match Lighting Your Grill Side BurnerRotisserie Burner Electronic Ignition Match Lighting Your Rotisserie Burner OFF / Arret / Apagado Rotisserie BurnerUsing the Rotisserie Operating the Electric Warming Drawer Cooking with the RotisserieHelpful Hints Maintenance TroubleshootingDay Grill Maintenance Schedule Cleaning the HoodAnnual Maintenance Annual Maintenance Main Burner Flame Pattern Cleaning the Spider/Insect ScreensCleaning the Main Burner Battery Replacement of Rotisserie Burner IgniterReplacing the Main Burners Guía del Propietario de la Parrilla de Gas Natural Solamente Para Unidades DE GAS Propano Líquido Peligros Y AdvertenciasMedidas Preventivas Importantes Solamente Para USO DomésticoImportante Ensamblaje Ubicando su ParrillaNivelado Instrucciones para la conexión a tierraRevisión de Fugas de Gas Instalación PortátilEnchufe el asador para alimentar corriente a los accesorios Operación NormalEncender su Parrilla Precalentar la ParrillaPara Parrillas de Gas Natural y Sistemas de Propano Poscalentamiento de la ParrillaHornilla Principal Encender Automáticamente Encender con Fósforos la Hornilla Principal de la ParrillaHornilla del Sistema Rotativo Encender Electrónicamente Hornilla Lateral Encender AutomáticamenteEncender con Fósforos su Sistema Rotativo Operando el Sistema Rotativo Usando el Sistema RotativoOperación del cajón de calentamiento eléctrico Cocinando con el Sistema RotativoDatos Útiles Mantenimiento ProblemasRutina de Mantenimiento para la Parrilla Cada 90 Días Limpiar la TapaMantenimiento Anual Mantenimiento Anual Patrón de Llama en la Hornilla Principal Limpiar las Mallas Contra Arañas/InsectosCambiando la Hornilla Principal Limpiando la Hornilla PrincipalGuide de l’utilisateur du barbecue au gaz naturel Pour LES Unités AU GAZ Propane Seulement Pour UNE Utilisation Domestique Uniquement Précautions ImportantesAssemblage Déterminer l’emplacement de votre grilMise à niveau Instructions de mise à la masseVérifications des fuites de gaz Installation portableFonctionnement normal Préchauffage du grilOuverture ou fermeture du couvercle pour le grillage Pour les grils de systèmes au gaz naturel et au propane Gril de post-chauffageAllumage par étincelle du brûleur principal Allumage par allumette du brûleur principal de votre grilAllumage par étincelle du brûleur latéral Allumage par allumette du brûleur latéral de votre grilAllumage électronique du brûleur de la rôtisserie Allumage par allumette du brûleur de votre rôtisserie Utilisation de la rôtisserie AvertissementsUtilisation du tiroir de chauffage électrique La cuisson avec la rôtisserieConseils pratiques Entretien DépannageHoraire d’entretien du gril de 90 jours Nettoyage du CouvercleNettoyage de l’acier inoxydable de la grille de cuisson Entretien annuelNettoyage des plaques de distribution de chaleur Nettoyage du boîtier du brûleurEntretien annuel Allure de la flamme du brûleur principal Nettoyage de l’écran contre les araignées et les insectesNettoyage du brûleur principal Remplacement des brûleurs principauxMeridian