Philips SC2003 user manual Lamp does not require replacement, Working principle

Page 8

8ENGLISH

Cordless operation for maximum freedom and flexibility Because the appliance runs on rechargeable batteries, it is portable and can be used anywhere.

Long-lasting battery for complete body and face treatment A fully charged battery provides a complete body and face treatment (upper lip, underarms, bikini line and lower legs) in one go, without recharging breaks.*

*Based on the average treatment times for each area and the recommended intensities for one user.

Lamp does not require replacement

Philips Lumea Precision Plus is equipped with a high-performance lamp which does not require replacement.This lamp can generate over

100,000 flashes and should enable you to continuously maintain results for more than 5 years* while saving money on expensive replacement lamps. *Based on average usage scenario and recommended treatment regime for one user.

How Philips’ Intense Pulsed Light technology works

Hair growth

Hair growth rates differ from person to person, depending on age, metabolism and other factors. However, everyone’s hair normally grows in 3 phases.

1 Growing phase (anagen phase)

The hair grows actively from the root. In this phase the concentration of melanin is highest. Melanin is responsible for the pigmentation of the hair. Melanin concentration is also the determining factor for the efficacy of this method. Only hairs in the growing phase are susceptible to treatment with light.

2 Degradation phase (catagen phase)

Hair growth stops and the root shrinks before the hair sheds.

3 Resting phase (telogen phase)

The old hair separates from its hair follicle and sheds.The follicle remains at rest until the biological clock tells it to become active again and grow a new hair.

Working principle

The appliance works by heating up the hair and root beneath the skin. The melanin in the hair and hair root absorbs the released light pulses.The darker the colour of the hair, the more light can be absorbed.This process stimulates the hair to go into the resting phase. 

The hair now sheds naturally and the hair growth is inhibited. Hairs can take one or two weeks to shed. Optimal hair removal cannot be obtained with a single session, since only hairs in the growing phase are susceptible to treatment with light. During a treatment, hairs on the treated area are usually in different stages of the hair growth cycle.To effectively treat all hairs you have to repeat the treatment every two weeks for a few times. An integrated optical filter ensures that no UV light reaches the skin and guarantees that the appliance is safe for the skin.

Image 8
Contents SC2003 Page Page Page SC2003 Table of contents EnglishIntroduction BenefitsThis appliance provides the following benefits Intense Pulsed Light IPL technology for home useLamp does not require replacement Working principleGeneral description To prevent damage English Switch off the appliance Electromagnetic fields EMFCharging Charge the appliance in the following wayAppliance Preparing for usePreparing treatment areas Setting the light intensity Recommended light intensitiesDark blond/light Brown/brown White/grey/red Light blondTanning advice Sun exposure before treatment Using the applianceSun exposure after treatment Tanning with artificial lightFirst use and skin test Choosing the right attachment Body attachmentPrecision attachment Subsequent use English Using the appliance on the legs Using the appliance in the bikini areaGuidelines for treatment Average treatment time Area Approx. treatment time Recommended attachmentHow to achieve optimal results Using the appliance on the underarmsUsing the appliance on the face upper lip, chin, sideburns After use Maintenance phaseRare side effects Storage Cleaning and maintenanceReddish filter glass inside the precision attachment Removing the rechargeable batteries EnvironmentFor product disposal, check the local current normalization Guarantee and support Support or read the separate worldwide guarantee leafletTechnical specifications Storage conditions Temperature 0 to +60CTransportation TroubleshootingAnesthetics with air, oxygen and nitrous oxide This is normal Problem Possible cause SolutionAppliance has to be reset Possible cause Solution Problem Problem Possible cause You do not use As often asRecommended Treatment interval again, but do not treat any areaSumário Este aparelho conta com os seguintes recursos IntroduçãoRecursos Princípio de funcionamento Não é necessário substituir a lâmpadaFase de crescimento fase Anágena Descrição geral ImportantePerigo AvisoPara evitar danos AtençãoPortuguês do Brasil Se tomar medicamentos imunossupressores Nunca use o aparelho nas seguintes áreasCampos eletromagnéticos EMF CarregamentoCarregue o aparelho da seguinte maneira Preparação para o usoDepilar conforme descrito abaixo Preparação das áreas de tratamentoEficaz AparelhoAjuste da intensidade de luz Intensidades de luz recomendadas 1 ImportanteExposição à luz solar após o tratamento Bronzeamento com luz artificialBronzeamento com cremes Utilização do aparelhoBocal de precisão Primeira utilização e teste de peleUso subsequente TratamentoDermatológicas neste capítulo para obter mais informações Intensidade, pressione o botãoÁrea Tempo aproximado do Bocal recomendado Tratamento Axilas Minuto por axilaLinha do biquíni Minuto por lateral Linha do biquíni inteira MinutosUso do aparelho na virilha Áreas em que o tratamento será realizadoUso do aparelho nas pernas Uso do aparelho nas axilas Uso do aparelho no rosto buço, queixo e costeletasDireta Como obter os melhores resultadosEtapa de manutenção Efeitos colaterais rarosApós o uso Artificial e exposição à luz solarLimpeza e manutenção Desligue o aparelho, desconecte-o da tomada e deixe esfriarRemoção das baterias recarregáveis ArmazenamentoMeio ambiente Garantia e suporte Especificações técnicas Modelo SC2003Taxa de tensão Taxa de frequênciaTemperatura e umidade ambiente Compatibilidade Eletromagnética Solução de problemas Problema Possível causa Solução bocal com o Para ser emitido não Anel de segurançaCorretamente sobre Aparelho sobre a Pele De emissão do flash de luzAparelho e/ou o Odor estranho Vidro do filtro estáSujo Você não raspouDo bocal está QuebradoPara trocar o aparelho Aparelho não é adequado para a sua cor de peleProblema Possível causa Aparelho não é adequado para a sua cor de pele ou dos pelosOs pelos começam Talvez você Crescer novamente Não tenha feitoPage 4222.100.2038.1