EXP1240 System Installation Guide | Revision 06 |
Valid server, folder, and firmware file name examples (handsets)
•tftp://update.abc.com/ipdect/firmware/Pegasus/PegasusSW_4181_v0019.fwu
•tftp://abc.com/firmware_update/Pegasus/PegasusSW_4181_v0007.fwu
•tftp://192.168.10.207/fwupdate/Pegasus/PegasusSW_4181_v0023.fwu
Configuring the Firmware Update Settings
Login to the base station interface (see page 16), and go to the Firmware Update screen.
Figure 30: Firmware Update server information
5)In the Firmware update server address field, enter the name or IP address of the TFTP server.
∘Enter the folder path between the server root and the Beatus or Pegasus folder.
∘Do not include the folder name for base stations (Beatus) or handsets or (Pegasus): these are added automatically).
∘This field must start with a forward slash (/).
∘Do not include a forward slash at the end of the field.
∘The table below shows how you would enter the server address and firmware path using the examples shown on page 41.
Table 7 Firmware path examples
Firmware update
server address
Firmware path
Firmware
folder
Firmware file name
Base station firmware files |
|
| |
|
|
|
|
update.abc.com | /ipdect/firmware | /Beatus/ | BeatusSW_4181_v0026.fwu |
|
|
|
|
abc.com | /firmware_update | /Beatus/ | BeatusSW_4181_v0001.fwu |
|
|
|
|
192.168.10.207 | /FWupdate | /Beatus/ | BeatusSW_4181_v0127.fwu |
|
|
|
|
© 2013 Uniden America Corp. | PROPRIETARY AND CONFIDENTIAL | Page 42 of 71 |