EXP1240 System Installation Guide | Revision 06 |
∘The IP Status field of the base station you are logged into should show This unit. Any other base stations in this chain should show Connected (i.e., connected to the network and functioning properly) as their IP status. If any base station shows Connection Loss as its IP status, that base station is not connected to the network or has lost power.
∘The primary base station always serves as its own sync source, so the DECT sync source field should display Primary:RPN{its own RPN}. The DECT Property field shows Primary.
∘This base station's DECT sync source will show (any) RPN and its DECT Property field will show Locked.
∘Check the DECT sync source
∘If the primary base station is not on the list or if the signal strength is below - 70 to
∘The DECT Chain appears at the bottom of the display and shows the synchronization source for all base stations in this system. Until the primary base station is selected as the DECT sync source, there will be a warning in the DECT Chain for this base station.
Figure 26: Base Station Group table, synchronization complete (Multi-cell screen)
13)When the system has finished synchronizing, repeat this process for each base station at Level 1.