EXP1240 System Installation Guide | Revision 06 | ||
|
|
|
|
| Parameter | Description |
|
|
|
|
|
|
| Select: |
|
|
| – Off – To not include any multi cell logs in the syslogs. This is the | |
|
| recommended setting unless requested otherwise by a | |
|
| technician. A lot of logs are generated when the other | |
|
| selections are chosen. |
|
|
| – Data Sync – To include in the syslogs logs regarding which | |
| Multi cell debug | signals are received from which IP addresses. Timeout handling | |
|
| and state changes are logged. |
|
|
| – Auto tree – To include in the syslogs logs regarding events | |
|
| triggering the reconfiguration of the DECT chain, and timeouts | |
|
| within Auto tree are logged. |
|
|
| – Both – To include both Data sync and Auto tree logs in the | |
|
| syslogs. |
|
|
|
|
|
| Table 27: DECT system settings parameters | |
|
|
|
Parameter | Description | |
|
|
|
| The radio network identity used by all base stations in a specific chain | |
DECT system RFPI | to communicate with each other. (See Appendix B: RFPI Number on | |
| page 71 for details.) | |
|
|
|
Auto configure |
|
|
DECT sync source | This setting should remain disabled. | |
tree |
|
|
|
| |
| Table 28: Base station settings parameters | |
|
|
|
Parameter
Number of SIP accounts before distributed load
Description
Enter the maximum number of handset registrations (up to 30) you want each base station in the chain to be able to handle. If the number of registered handsets at a particular base station goes beyond the number entered here, extra handsets will be distributed to other base stations in this chain.
© 2013 Uniden America Corp. | PROPRIETARY AND CONFIDENTIAL | Page 66 of 71 |