Uniden EXP1240 manual Setting. The intended audience is Level 1 or 2 technical

Page 58

EXP1240 System Installation Guide

Revision 06

Parameter

Upload of SIP Log

Description

Select Enabled to have this base station copy low-level SIP debug messages onto the configuration server. SIP logs are named in the format of {MAC_address}_SIP_{timestamp}.log. Unless you are troubleshooting a specific problem, leave this log disabled.

Trace Server

(for development purpose only)

 

 

Trace Server IP

(for development purpose only)

Address

 

 

 

Syslog Server IP

Enter the IP address of the server you want the base station to

Address

upload Syslogs to.

 

 

 

 

Syslog Server Port

If your syslog server is listening to a port other than 514 (the

default), enter that port number.

 

 

 

 

Select the level of messages you want the base station to log:

 

Disabled: the base station will not log any messages to the

 

server.

 

Normal Operation: Normal operation events are logged,

 

incoming call, outgoing calls, handset registration, DECT

 

location, and call lost due to busy, critical system erroprs,

Syslog Level

general system information. The Syslog Level should be at this

setting. The intended audience is Level 1 or 2 technical

 

 

support.

 

System Analyze: Handset roaming events are logged at this

 

level plus Normal Operation logs. The intended audience is

 

Level 1 or 2 technical support.

 

Debug: Low level debug logs plus System Analyse logs. The

 

intended audience are system developers.

 

 

© 2013 Uniden America Corp.

PROPRIETARY AND CONFIDENTIAL

Page 58 of 71

Image 58
Contents EXP1240 SIP Dect System Installation Guide Revision 06, July 7Contents Appendix a Software Reference Table of Figures List of Tables Dect system settings parameters Important Safety Instructions Check the Box ContentsManual Conventions About This DocumentPurpose and Audience Terms used in this manualTerms AbbreviationsHardware Setup Base StationConnecting the base station Base station LEDs and their meaningsBase mounting dimensions Wall mounting the base stationHandset and Charger Handset front viewCharging the battery Powering on the HandsetInitial System Configuration Using the Base Station Interface Summary Basic system configurationConfiguring General System Settings Home/Status screenChange Configuration and Management Settings Management screenChange the Default Password Change the Pstn Tones and Emergency DialingConfigure the Network Settings Screen Country screenConfigure Time Settings Time Settings screenConfiguring the SIP Server Settings Checking time settings updatesSelecting YES indicates If information in rport and received To edit an existing server Program the SIP ExtensionsTo delete a server Add Extension screen To edit an extension Register Handsets to ExtensionsTo delete extensions Extensions screen, no handsets registered To deregister a handset Extensions screen, three handsets registeredTiming Levels IntroductionSystem Chain ID and RPN Sample multi-cell system Summary Multi-cell system configuration Setting Up a Multi-cell SystemSample multi-cell system information Configuring the Primary Base Station Multi-cellscreen default valuesConfiguring Level 1 Base Stations Home/status screen primary base enabledMulti-cellscreen top after configuration EXP1240 System Installation Guide Configuring Base Stations at Level 2 and Up Base Station Group table, Level 1 complete Multi-cellscreenRemoving Base Stations from a Multi-Cell System Base Station Group table, Level 2 added Multi-cellscreenChanging the Primary Base Station in a Chain Multi cell Ready Keep-alive Primary Backing Up Configuration Settings Configuration screenSetting Up Firmware Folders Restoring a ConfigurationUpdating the Firmware Configuring the Firmware Update Settings Firmware path examplesFirmware Update screen Updating Base Station FirmwareUpdating Handsets To verify the firmware update Firmware update progress Extensions screenBase Station Configuration Interface Available ScreensGlobal Buttons and Options Home/Status Options Home/Status Screen Read OnlyHome/Status parameters Extensions Screen Extensions optionsAdd Extension and Edit Extension screens Extensions parameters read onlyParameter Description Extension Servers options Servers ScreenServers parameters SIP server outbound proxy address. Use one of these formats IP Settings parameters Network ScreenVlan Settings parameters Dhcp Options parametersNAT Settings parameters SIP/RTP Settings parametersManagement Settings parameters Management ScreenSetting. The intended audience is Level 1 or 2 technical Firmware Update Screen Firmware Update screen optionsUpdate Handsets parameters Time Settings parameters Time ScreenDST Web Security Screen Country ScreenCentral Directory Screen Multi Cell Screen Importing a new file will replace the existing contact listSettings for this unit parameters 71 for details Base Station Group parameters RPN DectConfiguration Screen read only Syslog Screen read only SIP Log Screen read only Appendix B Rfpi Numbers