Uniden EXP1240 manual NAT Settings parameters, SIP/RTP Settings parameters

Page 56

EXP1240 System Installation GuideRevision 06

 

Table 18: NAT Settings parameters

 

 

Parameter

Description

 

 

 

Select Enabled if you want the system to use RPORT in SIP messages.

 

Enable RPORT

This will also cause the base stations to send Keep Alive messages

according to the Keep Alive time. Otherwise, leave this feature

 

 

Disabled.

 

 

 

Enter the number of seconds (as a positive integer) between each keep-

 

Keep alive time

alive message sent to maintain NAT address assignments. The default

 

value is 90.

 

 

 

Table 19: SIP/RTP Settings parameters

 

 

Parameter

Description

 

 

 

 

 

Enter the port number the server should use for the first user agent

Local SIP port

(UA) instance. Successive ports will be automatically assigned for

 

additional UA instances. The default port number is 5060.

 

 

SIP ToS/QoS

Enter the Type of Service or Quality of Service priority code for SIP call

control traffic. The default value is 0x68 (104 in decimal notation).

 

 

 

 

Enter the number of the first RTP port to use. Successive ports will be

 

RTP port

automatically assigned up to the number entered below. The default

 

port is 50004.

 

 

RTP port range

Enter the number of ports that can be used for RTP audio streaming

(the default is 40).

 

 

 

 

 

RTP ToS/QoS

Enter the Type of Service or Quality of Service priority code for RTP

traffic; the default is 0xB8.

 

 

 

© 2013 Uniden America Corp.

PROPRIETARY AND CONFIDENTIAL

Page 56 of 71

Image 56
Contents EXP1240 SIP Dect System Installation Guide Revision 06, July 7Contents Appendix a Software Reference Table of Figures List of Tables Dect system settings parameters Important Safety Instructions Check the Box ContentsAbout This Document Purpose and AudienceManual Conventions Terms used in this manualTerms AbbreviationsHardware Setup Base StationConnecting the base station Base station LEDs and their meaningsBase mounting dimensions Wall mounting the base stationHandset and Charger Handset front viewCharging the battery Powering on the HandsetInitial System Configuration Using the Base Station Interface Summary Basic system configurationConfiguring General System Settings Home/Status screenChange Configuration and Management Settings Management screenChange the Default Password Change the Pstn Tones and Emergency DialingConfigure the Network Settings Screen Country screenConfigure Time Settings Time Settings screenConfiguring the SIP Server Settings Checking time settings updatesSelecting YES indicates If information in rport and received To delete a server Program the SIP ExtensionsTo edit an existing server Add Extension screen To delete extensions Register Handsets to ExtensionsTo edit an extension Extensions screen, no handsets registered To deregister a handset Extensions screen, three handsets registeredSystem Chain ID and RPN IntroductionTiming Levels Sample multi-cell system Sample multi-cell system information Setting Up a Multi-cell SystemSummary Multi-cell system configuration Configuring the Primary Base Station Multi-cellscreen default valuesConfiguring Level 1 Base Stations Home/status screen primary base enabledMulti-cellscreen top after configuration EXP1240 System Installation Guide Configuring Base Stations at Level 2 and Up Base Station Group table, Level 1 complete Multi-cellscreenRemoving Base Stations from a Multi-Cell System Base Station Group table, Level 2 added Multi-cellscreenChanging the Primary Base Station in a Chain Multi cell Ready Keep-alive Primary Backing Up Configuration Settings Configuration screenUpdating the Firmware Restoring a ConfigurationSetting Up Firmware Folders Configuring the Firmware Update Settings Firmware path examplesFirmware Update screen Updating Base Station FirmwareUpdating Handsets To verify the firmware update Firmware update progress Extensions screenBase Station Configuration Interface Available ScreensGlobal Buttons and Options Home/Status parameters Home/Status Screen Read OnlyHome/Status Options Extensions Screen Extensions optionsAdd Extension and Edit Extension screens Extensions parameters read onlyParameter Description Extension Servers parameters Servers ScreenServers options SIP server outbound proxy address. Use one of these formats IP Settings parameters Network ScreenVlan Settings parameters Dhcp Options parametersNAT Settings parameters SIP/RTP Settings parametersManagement Settings parameters Management ScreenSetting. The intended audience is Level 1 or 2 technical Firmware Update Screen Firmware Update screen optionsUpdate Handsets parameters Time Settings parameters Time ScreenDST Central Directory Screen Country ScreenWeb Security Screen Multi Cell Screen Importing a new file will replace the existing contact listSettings for this unit parameters 71 for details Base Station Group parameters RPN DectConfiguration Screen read only Syslog Screen read only SIP Log Screen read only Appendix B Rfpi Numbers