Appendix B: RFPI Numbers

The RFPI is constructed from 4 different variables which make up the 10 characters (represented by N in the format 0xNN,0xNN,0xNN,0xNN,0xNN):

Access Rights Class (ARC), character 1

The network identity structure used by terminals in multi-cell. Private multi-cell systems use the default value of 1.

Equipment Installer's Code (EIC), characters 2 through 5

A preset code that allows terminals to distinguish between separate DECT networks. The minimum value is 0000; the maximum is FFFF. The default value for the EXP1240 system is 16E6.

Fixed Part Number (FPN), characters 6 through 8:

A geographically unique identity transmitted to DECT networks to help distinguish between communications in different cells or chains. The minimum value is 001; the maximum is FFF.

Location Area Length (LAL), characters 9 and 10:

A unique code sent to the terminal during location registration to determine the size of the cell area. The minimum value is 00; the maximum is FF.

An example RFPI would be

ARC (char 1)

1

EIC (chars 2-5)

16E6

FPN (chars 6-8)

000

LAL (chars 9-10)

FF

The values are collapsed into a single 10-character string (116E6000FF), then the string is separated into 5 pairs of 2 characters each:

Pair 1

11

Pair 2

6E

Pair 3

60

Pair 4

00

Pair 5

FF

Each pair is written as a 2-character HEX value (i.e., 0x is added to the front):

Pair 1

0x11

Pair 2

0x6E

Pair 3

0x60

Pair 4

0x00

Pair 5

0xFF

The HEX values are separated with commas, and the final result is displayed in the field as 0x11,0x6E,0x60,0x00,0xFF.

© 2013 Uniden America Corp.

PROPRIETARY AND CONFIDENTIAL

Page 71 of 71

Image 71
Contents Revision 06, July 7 EXP1240 SIP Dect System Installation GuideContents Appendix a Software Reference Table of Figures List of Tables Dect system settings parameters Check the Box Contents Important Safety InstructionsTerms used in this manual About This DocumentPurpose and Audience Manual ConventionsAbbreviations TermsBase Station Hardware SetupBase station LEDs and their meanings Connecting the base stationWall mounting the base station Base mounting dimensionsHandset front view Handset and ChargerPowering on the Handset Charging the batteryInitial System Configuration Summary Basic system configuration Using the Base Station InterfaceHome/Status screen Configuring General System SettingsManagement screen Change Configuration and Management SettingsChange the Pstn Tones and Emergency Dialing Change the Default PasswordCountry screen Configure the Network Settings ScreenTime Settings screen Configure Time SettingsChecking time settings updates Configuring the SIP Server SettingsSelecting YES indicates If information in rport and received To delete a server Program the SIP ExtensionsTo edit an existing server Add Extension screen To delete extensions Register Handsets to ExtensionsTo edit an extension Extensions screen, no handsets registered Extensions screen, three handsets registered To deregister a handsetSystem Chain ID and RPN IntroductionTiming Levels Sample multi-cell system Sample multi-cell system information Setting Up a Multi-cell SystemSummary Multi-cell system configuration Multi-cellscreen default values Configuring the Primary Base StationHome/status screen primary base enabled Configuring Level 1 Base StationsMulti-cellscreen top after configuration EXP1240 System Installation Guide Base Station Group table, Level 1 complete Multi-cellscreen Configuring Base Stations at Level 2 and UpBase Station Group table, Level 2 added Multi-cellscreen Removing Base Stations from a Multi-Cell SystemChanging the Primary Base Station in a Chain Multi cell Ready Keep-alive Primary Configuration screen Backing Up Configuration SettingsUpdating the Firmware Restoring a ConfigurationSetting Up Firmware Folders Firmware path examples Configuring the Firmware Update SettingsUpdating Base Station Firmware Firmware Update screenUpdating Handsets Firmware update progress Extensions screen To verify the firmware updateAvailable Screens Base Station Configuration InterfaceGlobal Buttons and Options Home/Status parameters Home/Status Screen Read OnlyHome/Status Options Extensions options Extensions ScreenExtensions parameters read only Add Extension and Edit Extension screensParameter Description Extension Servers parameters Servers ScreenServers options SIP server outbound proxy address. Use one of these formats Network Screen IP Settings parametersDhcp Options parameters Vlan Settings parametersSIP/RTP Settings parameters NAT Settings parametersManagement Screen Management Settings parametersSetting. The intended audience is Level 1 or 2 technical Firmware Update screen options Firmware Update ScreenUpdate Handsets parameters Time Screen Time Settings parametersDST Central Directory Screen Country ScreenWeb Security Screen Importing a new file will replace the existing contact list Multi Cell ScreenSettings for this unit parameters 71 for details RPN Dect Base Station Group parametersConfiguration Screen read only Syslog Screen read only SIP Log Screen read only Appendix B Rfpi Numbers