SETUPS

To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

5.1 Digital Setup

This illustration shows how to connect a 5.1 digital setup

Left monitor is set as System Controller by leaving out the TC Link button on the rear panel.

Left monitor receives both Left and Right Input signal. Right channel is fed via the TC -LINK RJ-45 connection from the Left to Right.

LS monitor receives both Left and Right Surround channels. The RS channel is fed via the RJ-45 connection from LS to RS.

Center monitor receives both Center and LFE channels. The LFE monitor is fed via the RJ-45 connection from Center to LFE.

The Remote, AIR Soft and AIR PC-IP can be connected to any available TC LINK Out connection.

To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

5.1 Analog Setup

This illustration shows how to connect a 5.1 analog setup

Left monitor is set as System Controller by leaving out the TC Link button on the rear panel.

Left monitor receives both Left and Right Input signal. Right channel is fed via the TC -LINK RJ-45 connection from the Left to Right.

LS monitor receives both Left and Right Surround channels. The RS channel is fed via the RJ-45 connection from LS to RS.

Center monitor receives both Center and LFE channels. The LFE monitor is fed via the RJ-45 connection from Center to LFE.

With no Bass-management active the Sub will play only the LFE channel.

With Bass-management activated Low Frequency information from the 5 main channels is extracted and distributed to the Sub where it is summed with the LFE channel.

The Remote, AIR Soft and AIR PC-IP can be connected to any available TC LINK Out connection.

The setups will ONLY operate correctly if connected according to the illustrations!

8

Image 10
Contents Page Page Important Safety Instructions Voltage Line plug according to standardPage Table of Contents Quick Setup Reference Quick Setup Reference Operational Overview Main DisplayStereo Setup with mono Subs SetupsStereo Setup Stereo Setup with stereo SubsThis illustration shows how to connect a 5.1 digital setup Digital SetupAnalog Setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Digital setup This illustration shows how to connect a 5.3 Analog setupThis illustration shows how to connect a 6.1 Analog setup Dig/6 MasterAnalog/Digital setup Stereo Setup With Chains on L & ROther Chained Setups Analog connectionsDigital 192 kHz Digital Setup Break IntroductionThis Manual Product ConceptMaster Unit Remote ControlCommon Features Slave & Sub UnitsSlave/Sub Rear Panel Description MasterMaster Unit Analog I/O Optional Digital I/O cardEnter key Cursor UP/DOWN keys AIR DisplayOverload Indication Overload Indication LEDBasic operation in all menus Press Enter to access the Select ModeParameter Description Main DisplaySet Monitor Task Setup MenuSetup External ClockRecall LFE channel noteStore Placing the Monitors OverviewOn the bridge / Console Close to wall / WallOther situations Checking by ear when listening to the signals In phase Checking the placementPhase checking EvaluationEqualizing NextAcoustic level calibration Calibrating Main Monitors CurvesInterchannel calibration CurvePlacing the Subwoofer Low frequency sweeps EvaluationControlling standing waves Checking summing phase cancellationTo Calibrate Checking the CrosspointLFE Gain PhasePhase Introduction PolarityGood acoustics AcousticsReverberation time Sabines formula Membrane absorbers AbsorbersDiffusers Absorbtion or diffusion ? Resonance absorbersBackground Info Acoustics Standing WavesRoom modes Axial Tangential RadialHow to prohibit standing waves How does the standing waves influence the sound field?Acoustics Background Info Comb Filtering Or + Dip frequenciesRear wall cancellation Subwoofer Background Info SubwooferCross-overs Subwoofer & LFE Channel Background InfoLFE Channel Low Pass LFE GainAcoustic summation of audio signals Delaying Monitors LINE-UP & CalibrationCinema setup LINE-UP & Calibration Background Info How to measure the sound pressure?Calibration of 5.1 in an ITU-775 arrangement AIR Remote Remote Control FeaturesIntroduction REF Level 1-3 keys Preset 1/3 and 2/4 keysVolume potentiometer Shift keyAIR Soft Navigating AIR SoftMain ToolsPreset List NetworkSystem Setup Calibrate AIR-Base Chained monitorsGlobal Parameters Reset ProceduresMiscellaneous Local ParametersAES/EBU Standard cables CablesTC Link Standard Cat-5 cables Serial to Cat-5 cableAIR 6 & AIR 15 Master and Slave AIR 20 & AIR 25 Master and SlaveAIR-Base-1 & AIR-Base-2 AIR BaseGeneral for all Products Room & DistanceAIR Remote specs Delay in System & Error Messages ETC Error messages etcCertificate Of Conformity Certificate of ConformityAIR AIR-Base Preset List # Name