AIR SOFT

Calibrated Level

Level calibration of the selected monitor.

Relative Level

Preset volume for the selected monitor relative to the calibrated and global volume.

Use Parametric EQ

This will be marked if the Parametric EQ is activated via the AIR PC-IP. Bass and Treble settings will be disabled.

Bass/Treble Range: -6dB to +6dB

Bass and Treble adjustment for the selected monitor. These handles are not available when the Parametric EQ is activated via AIR PC-IP.

Mute

Press to mute the selected monitor.

Solo

Press to solo the selected monitor.

Pink Noise

Press to generate Pink Noise in the selected monitor.

Calibrate - AIR-Base

Mute

Solo

Pink Noise

Via this Calibrate screen, parameters and settings for the Subwoofers are controlled.

The screen is accessed via the Main Screen by holding the cursor above the desired Sub and selecting the hammer icon.

Phase Range: 0-180°

To time-compensate if the Sub is not placed according to the ITU 775 recommendations. There are individual Phase settings for each of the Bass Management Cross-over frequencies. Once set, these are stored as Global settings.

Polarity

Range: 0 or 180 deg.

Mark to activate.

Calibrated Level

Level calibration of the selected monitor.

Relative Level

Preset volume for the selected monitor relative to the calibrated and global volume.

LFE Gain Range: 0 to 14dB

With this parameter you can boost the gain of the LFE channel.

LFE Low Pass Filter

Mark to activate.

Mute

Press to mute the selected Sub.

Solo

Press to solo the selected Sub.

Pink Noise

Press to generate Pink Noise in the selected Sub.

Chained monitors

If several monitors are chained on the same task (e.g. LSur-LSChain) a dropdown menu will be present as illustrated below.

To calibrate a chained monitor simply select from the list.

Chained monitors will also be indicated in the Main screen.

This symbol indicates that there are two monitors chained on this specific position.

50

Image 52
Contents Page Page Important Safety Instructions Voltage Line plug according to standardPage Table of Contents Quick Setup Reference Quick Setup Reference Operational Overview Main DisplaySetups Stereo SetupStereo Setup with mono Subs Stereo Setup with stereo SubsDigital Setup Analog SetupThis illustration shows how to connect a 5.1 digital setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Digital setup This illustration shows how to connect a 5.3 Analog setupThis illustration shows how to connect a 6.1 Analog setup Dig/6 MasterStereo Setup With Chains on L & R Other Chained SetupsAnalog/Digital setup Analog connectionsDigital 192 kHz Digital Setup Introduction This ManualBreak Product ConceptRemote Control Common FeaturesMaster Unit Slave & Sub UnitsRear Panel Description Master Master Unit Analog I/OSlave/Sub Optional Digital I/O cardAIR Display Overload IndicationEnter key Cursor UP/DOWN keys Overload Indication LEDPress Enter to access the Select Mode Parameter DescriptionBasic operation in all menus Main DisplaySetup Menu SetupSet Monitor Task External ClockRecall LFE channel noteStore Placing the Monitors OverviewOn the bridge / Console Close to wall / WallOther situations Checking the placement Phase checkingChecking by ear when listening to the signals In phase EvaluationEqualizing NextCalibrating Main Monitors Curves Interchannel calibrationAcoustic level calibration CurvePlacing the Subwoofer Low frequency sweeps EvaluationChecking summing phase cancellation To CalibrateControlling standing waves Checking the CrosspointPhase Phase IntroductionLFE Gain PolarityGood acoustics AcousticsReverberation time Sabines formula Absorbers DiffusersMembrane absorbers Absorbtion or diffusion ? Resonance absorbersBackground Info Acoustics Standing WavesRoom modes Axial Tangential RadialHow to prohibit standing waves How does the standing waves influence the sound field?Acoustics Background Info Comb Filtering Or + Dip frequenciesRear wall cancellation Subwoofer Background Info SubwooferSubwoofer & LFE Channel Background Info LFE ChannelCross-overs Low Pass LFE GainAcoustic summation of audio signals Delaying Monitors LINE-UP & CalibrationCinema setup LINE-UP & Calibration Background Info How to measure the sound pressure?Calibration of 5.1 in an ITU-775 arrangement AIR Remote Remote Control FeaturesIntroduction Preset 1/3 and 2/4 keys Volume potentiometerREF Level 1-3 keys Shift keyAIR Soft Navigating AIR SoftMain ToolsPreset List NetworkSystem Setup Calibrate AIR-Base Chained monitorsReset Procedures MiscellaneousGlobal Parameters Local ParametersCables TC Link Standard Cat-5 cablesAES/EBU Standard cables Serial to Cat-5 cableAIR 6 & AIR 15 Master and Slave AIR 20 & AIR 25 Master and SlaveAIR-Base-1 & AIR-Base-2 AIR BaseGeneral for all Products Room & DistanceAIR Remote specs Delay in System & Error Messages ETC Error messages etcCertificate Of Conformity Certificate of ConformityAIR AIR-Base Preset List # Name