Dynaudio Air Series manual Equalizing, Next

Page 26

CHECKING - PLACEMENT OF THE MONITORS

Equalizing

The AIR System menu offers a two-band shelving type equalizer. This can be used individually on each monitor, and it is implemented for a fine adjustment of the tonal balance.

Range:

±6 dB

Adjustment step:

0.5 dB

Band I:

100 Hz - 1 kHz

Band II:

1 kHz - 5 kHz

Filter type:

Shelving

You should be very careful using this tool if you are doing the adjustment by ear. In a room with good acoustics equalizing should not be necessary at all.

As a test signal you can use full bandwidth pink noise (tracks 2 or 13) on the test-CD

In a room that you feel heavily over damped at higher frequencies you may wish to ad some level in the high end in order to get the right balance. Do it with care then.

In a highly reflective room you may wish to attenuate the high frequencies.

If you have made a good job placing the monitor in a proper position you should not touch the low frequency band.

Notice: If you have done any adjustments using the equalizer, you should leave the room and come back 15 minutes later bringing some music, that you know well. Play this music. Now your first impression is very important for the assessment of the tonal balance of the monitor system. Listening during a long time will make the hearing perform a change in the perceived timbre. This is what we can compare to the "white balance" of the eye. After a short time you are getting used to a new tonal balance or timbre. What sounds "cool" or "fat" then is not necessarily sounding right for monitoring purposes.

Additional Equalizing can be done via the AIR PC-IP

Installers Software.

AIR PC-IP- Advanced Installers PC - Interface Packages The Installers software includes a 4 band Parametric EQ, for more precise EQ adjustment of each monitor.

Next

Go to: Calibrating the main monitor setup.

Read more in the Background Information chapter.

24

Image 26
Contents Page Page Important Safety Instructions Voltage Line plug according to standardPage Table of Contents Quick Setup Reference Quick Setup Reference Operational Overview Main DisplayStereo Setup with mono Subs SetupsStereo Setup Stereo Setup with stereo SubsThis illustration shows how to connect a 5.1 digital setup Digital SetupAnalog Setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Digital setup This illustration shows how to connect a 5.3 Analog setupThis illustration shows how to connect a 6.1 Analog setup Dig/6 MasterAnalog/Digital setup Stereo Setup With Chains on L & ROther Chained Setups Analog connectionsDigital 192 kHz Digital Setup Break IntroductionThis Manual Product ConceptMaster Unit Remote ControlCommon Features Slave & Sub UnitsSlave/Sub Rear Panel Description MasterMaster Unit Analog I/O Optional Digital I/O cardEnter key Cursor UP/DOWN keys AIR DisplayOverload Indication Overload Indication LEDBasic operation in all menus Press Enter to access the Select ModeParameter Description Main DisplaySet Monitor Task Setup MenuSetup External ClockStore LFE channel noteRecall Placing the Monitors OverviewOther situations Close to wall / WallOn the bridge / Console Checking by ear when listening to the signals In phase Checking the placementPhase checking EvaluationEqualizing NextAcoustic level calibration Calibrating Main Monitors CurvesInterchannel calibration CurvePlacing the Subwoofer Low frequency sweeps EvaluationControlling standing waves Checking summing phase cancellationTo Calibrate Checking the CrosspointLFE Gain PhasePhase Introduction PolarityReverberation time AcousticsGood acoustics Sabines formula Membrane absorbers AbsorbersDiffusers Absorbtion or diffusion ? Resonance absorbersBackground Info Acoustics Standing WavesRoom modes Axial Tangential RadialHow to prohibit standing waves How does the standing waves influence the sound field?Acoustics Background Info Comb Filtering Or + Dip frequenciesRear wall cancellation Subwoofer Background Info SubwooferCross-overs Subwoofer & LFE Channel Background InfoLFE Channel Low Pass LFE GainCinema setup Delaying Monitors LINE-UP & CalibrationAcoustic summation of audio signals Calibration of 5.1 in an ITU-775 arrangement How to measure the sound pressure?LINE-UP & Calibration Background Info Introduction Remote Control FeaturesAIR Remote REF Level 1-3 keys Preset 1/3 and 2/4 keysVolume potentiometer Shift keyAIR Soft Navigating AIR SoftMain ToolsPreset List NetworkSystem Setup Calibrate AIR-Base Chained monitorsGlobal Parameters Reset ProceduresMiscellaneous Local ParametersAES/EBU Standard cables CablesTC Link Standard Cat-5 cables Serial to Cat-5 cableAIR 6 & AIR 15 Master and Slave AIR 20 & AIR 25 Master and SlaveAIR-Base-1 & AIR-Base-2 AIR BaseAIR Remote specs Room & DistanceGeneral for all Products Delay in System & Error Messages ETC Error messages etcAIR AIR-Base Certificate of ConformityCertificate Of Conformity Preset List # Name