Dynaudio Air Series manual Setup Menu, Set Monitor Task, External Clock, Calibrate Monitor

Page 21

PARAMETER DESCRIPTION

Setup Menu

• Press ENTER to access sub-menus

Set Monitor Task

For the System Controller - Master monitor to identify and operate all monitors in the setup, each monitor must be given one of the following tasks indicating function and position.

Press ENTER to access task options

Use ARROW keys to select task

Press ENTER to confirm selected task

Following tasks can be given:

-

No task

-

LsChain

-

L Front

-

RsChain

-

R Front

-

CsChain

-

Center

-

L Inner

-

(C) Sub

-

R Inner

-

L Sub

-

CustMast

-

R Sub

-

CustSlaR

-

L Sur

-

CustSlaL

-R Sur

-C Sur

Setup

Press ENTER to enter select mode. Select mode is indicated by “ * ”

Press ENTER to confirm choice

Empty:

No selection

Custom:

For custom configurations.

Stereo analog:

Two monitor stereo setup with analog* Inputs selected.

Stereo Digital:

Two monitor stereo setup with digital Inputs selected.

5.1 Analog:

5.1 setup with analog* Inputs selected.

5.1 Digital

5.1 setup with digital Inputs selected.

6.1 Analog

5.1Setup + Center surround on a separate channel gives the 6.1 setup.

6.1 Digital

5.1Setup + Center surround on a separate channel gives the 6.1 setup.

5.3 Analog

Analog setup with 5 monitors and 3 subs

5.3 Digital

Digital setup with 5 monitors and 3 subs

*Analog Inputs are only available with an optional analog card installed.

5.1 Digital/6 Master

5.1Setup using one Master with optional Digital I/o card installed, 4 slave monitors (or masters set as slave) and 1 sub.

External Clock

• Press ENTER to access sub-menus

BNC Sync On:

The monitor attempts to lock on the Word Clock BNC.

BNC Sync Off:

The monitor will attempt to lock on the AES Input.

Calibrate Monitor

Press ENTER

Select monitor to calibrate using the ARROW keys

Press ENTER

19

Image 21
Contents Page Page Voltage Line plug according to standard Important Safety InstructionsPage Table of Contents Quick Setup Reference Quick Setup Reference Main Display Operational OverviewStereo Setup SetupsStereo Setup with mono Subs Stereo Setup with stereo SubsAnalog Setup Digital SetupThis illustration shows how to connect a 5.1 digital setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Analog setup This illustration shows how to connect a 5.3 Digital setupDig/6 Master This illustration shows how to connect a 6.1 Analog setupOther Chained Setups Stereo Setup With Chains on L & RAnalog/Digital setup Analog connectionsDigital 192 kHz Digital Setup This Manual IntroductionBreak Product ConceptCommon Features Remote ControlMaster Unit Slave & Sub UnitsMaster Unit Analog I/O Rear Panel Description MasterSlave/Sub Optional Digital I/O cardOverload Indication AIR DisplayEnter key Cursor UP/DOWN keys Overload Indication LEDParameter Description Press Enter to access the Select ModeBasic operation in all menus Main DisplaySetup Setup MenuSet Monitor Task External ClockLFE channel note RecallStore Overview Placing the MonitorsClose to wall / Wall On the bridge / ConsoleOther situations Phase checking Checking the placementChecking by ear when listening to the signals In phase EvaluationNext EqualizingInterchannel calibration Calibrating Main Monitors CurvesAcoustic level calibration CurvePlacing the Subwoofer Evaluation Low frequency sweepsTo Calibrate Checking summing phase cancellationControlling standing waves Checking the CrosspointPhase Introduction PhaseLFE Gain PolarityAcoustics Good acousticsReverberation time Sabines formula Diffusers AbsorbersMembrane absorbers Absorbtion or diffusion ? Resonance absorbersStanding Waves Background Info AcousticsAxial Tangential Radial Room modesHow does the standing waves influence the sound field? How to prohibit standing wavesAcoustics Background Info Comb Filtering Dip frequencies Or +Rear wall cancellation Subwoofer Subwoofer Background InfoLFE Channel Subwoofer & LFE Channel Background InfoCross-overs Low Pass LFE GainDelaying Monitors LINE-UP & Calibration Acoustic summation of audio signalsCinema setup How to measure the sound pressure? LINE-UP & Calibration Background InfoCalibration of 5.1 in an ITU-775 arrangement Remote Control Features AIR RemoteIntroduction Volume potentiometer Preset 1/3 and 2/4 keysREF Level 1-3 keys Shift keyNavigating AIR Soft AIR SoftTools MainNetwork Preset ListSystem Setup Chained monitors Calibrate AIR-BaseMiscellaneous Reset ProceduresGlobal Parameters Local ParametersTC Link Standard Cat-5 cables CablesAES/EBU Standard cables Serial to Cat-5 cableAIR 20 & AIR 25 Master and Slave AIR 6 & AIR 15 Master and SlaveAIR Base AIR-Base-1 & AIR-Base-2Room & Distance General for all ProductsAIR Remote specs Error messages etc Delay in System & Error Messages ETCCertificate of Conformity Certificate Of ConformityAIR AIR-Base # Name Preset List