Dynaudio Air Series manual This illustration shows how to connect a 5.3 Digital setup

Page 11

To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

SETUPS

5.3 Digital Setup

This illustration shows how to connect a 5.3 Digital setup

• Center is set as System Controller by leaving out the TC Link button on the rear panel.

• Left monitor receives both Left and LS signal. The LS monitor is fed via the TC LINK RJ-45 connection form Left to LS.

• Center monitor receives both Center and LFE signal. The LFE monitor is fed via the TC LINK RJ-45 connection from Center to LFE.

• Right monitor receives both Right and RS signal. The RS monitor is fed via the TC LINK RJ-45 connection from Right to RS.

• With Bass-management “off” Left and Right Subs receives no signal.

• With Bass management “on”:

-Low frequency information from Left and LS is extracted and fed to Left Sub.

-Low frequency information from Right and RS is extracted and fed to Right Sub.

-Low frequency information from Center is extracted, summed with the LFE channel and fed to Center Sub.

The Remote, AIR Soft and AIR PC-IP can be connected to any available TC LINK Out connection.

5.3 Analog Setup

This illustration shows how to connect a 5.3 Analog setup.

Please see description on 5.3 Digital Setup above regarding Bass-management but notice how to connect the Analog signals:

• Left channel to Left Input on the Left monitor.

• Left Surround channel to Right Input on the Left monitor.

• Center channel to the Left Input on the Center monitor.

LFE channel to the Right Input on the Center monitor.

Right channel to the Left Input on the Right monitor.

• Right Surround channel to Right Input on the Right monitor.

• The Remote, AIR Soft and AIR PC-IP can be connected to any available TC LINK Out connection.

The setups will ONLY operate correctly if connected according to the illustrations!

9

Image 11
Contents Page Page Voltage Line plug according to standard Important Safety InstructionsPage Table of Contents Quick Setup Reference Quick Setup Reference Main Display Operational OverviewStereo Setup with stereo Subs SetupsStereo Setup Stereo Setup with mono SubsThis illustration shows how to connect a 5.1 analog setup Digital SetupAnalog Setup This illustration shows how to connect a 5.1 digital setupThis illustration shows how to connect a 5.3 Analog setup This illustration shows how to connect a 5.3 Digital setupDig/6 Master This illustration shows how to connect a 6.1 Analog setupAnalog connections Stereo Setup With Chains on L & ROther Chained Setups Analog/Digital setupDigital 192 kHz Digital Setup Product Concept IntroductionThis Manual BreakSlave & Sub Units Remote ControlCommon Features Master UnitOptional Digital I/O card Rear Panel Description MasterMaster Unit Analog I/O Slave/SubOverload Indication LED AIR DisplayOverload Indication Enter key Cursor UP/DOWN keysMain Display Press Enter to access the Select ModeParameter Description Basic operation in all menusExternal Clock Setup MenuSetup Set Monitor TaskStore LFE channel noteRecall Overview Placing the MonitorsOther situations Close to wall / WallOn the bridge / Console Evaluation Checking the placementPhase checking Checking by ear when listening to the signals In phaseNext EqualizingCurve Calibrating Main Monitors CurvesInterchannel calibration Acoustic level calibrationPlacing the Subwoofer Evaluation Low frequency sweepsChecking the Crosspoint Checking summing phase cancellationTo Calibrate Controlling standing wavesPolarity PhasePhase Introduction LFE GainReverberation time AcousticsGood acoustics Sabines formula Absorbtion or diffusion ? Resonance absorbers AbsorbersDiffusers Membrane absorbersStanding Waves Background Info AcousticsAxial Tangential Radial Room modesHow does the standing waves influence the sound field? How to prohibit standing wavesAcoustics Background Info Comb Filtering Dip frequencies Or +Rear wall cancellation Subwoofer Subwoofer Background InfoLow Pass LFE Gain Subwoofer & LFE Channel Background InfoLFE Channel Cross-oversCinema setup Delaying Monitors LINE-UP & CalibrationAcoustic summation of audio signals Calibration of 5.1 in an ITU-775 arrangement How to measure the sound pressure?LINE-UP & Calibration Background Info Introduction Remote Control FeaturesAIR Remote Shift key Preset 1/3 and 2/4 keysVolume potentiometer REF Level 1-3 keysNavigating AIR Soft AIR SoftTools MainNetwork Preset ListSystem Setup Chained monitors Calibrate AIR-BaseLocal Parameters Reset ProceduresMiscellaneous Global ParametersSerial to Cat-5 cable CablesTC Link Standard Cat-5 cables AES/EBU Standard cablesAIR 20 & AIR 25 Master and Slave AIR 6 & AIR 15 Master and SlaveAIR Base AIR-Base-1 & AIR-Base-2AIR Remote specs Room & DistanceGeneral for all Products Error messages etc Delay in System & Error Messages ETCAIR AIR-Base Certificate of ConformityCertificate Of Conformity # Name Preset List