Dynaudio Air Series LINE-UP & Calibration Background Info, How to measure the sound pressure?

Page 45

LINE-UP & CALIBRATION - BACKGROUND INFO

Calibration of 5.1 in an ITU-775 arrangement

In a 5.1 system based on the ITU arrangement, all main channels have in principle the same conditions: there is one monitor per channel and each is placed the same distance from the listener. Internationally, there is however neither agreement on the level nor on the bandwidth for the noise signals that is used for acoustic calibration. Pink noise is good since it includes all frequencies, however it is impractical due to its "unsettled" character, which makes it difficult to measure at low frequencies.

Surround Sound Forum

Surround Sound Forum is a German interest group composed of the VDT (sound technicians), the IRT and the SRT. The SSF has prepared guidelines, which are generally accepted in Europe. Three test signals are specified in it, which are recorded at -18 dBFS (RMS).

 

 

 

 

 

 

 

 

 

Measurement Signals

 

 

Listening Level

 

 

 

 

 

 

 

 

 

 

 

 

Signal

PPM level

PPM level

RMS level

Sound pressure

Sound pressure

(only in one channel)

t <0,1 ms

t <10 ms

 

 

level

 

level

 

 

 

 

 

 

 

SLOW

 

SLOW

 

 

[dB]

[dB]

[dB]

[dB]

 

[dB(A)]

1 kHz sine

-18

-18

-18

 

 

 

Pink noise 20 Hz-20 kHz

-9

-13

-18

82

78

Pink noise 200 Hz-20 kHz

-11

-15

-20

80

78

SMPTE

The corresponding standard from SMPTE (RP155) uses a standard of -20 dBFS for the reference level. Here, the C- weighted sound pressure level of a 500 to 2 kHz noise signal ends up at 83 dB.

Calibration of cinema systems

In a cinema, the listeners are sitting far from the monitors. Presumably, the majority sits in the diffuse sound field. In any event, attempts are made to establish a diffuse sound field from the surround monitors. Hence when the sound pressure is measured inside the cinema or in a mixing theatre it must be averaged over many different measurement locations. The typical basis for the majority of the standards is at least four locations. If there are different areas for the audience, for example main floor and balcony, measurement should be made in at least four locations in each. Before this measurement can be performed, the system's frequency response must also be in order.

How to measure the sound pressure?

Sound level meter or microphone

If you are used to perform acoustic measurements you probably already own a sound level meter. This can be used for the level calibration of the monitors.

If you do not have a sound level meter, there still is another possibility:

Take an omni-directional microphone. (This is also called a pressure microphone). A studio condenser microphone is normally preferred but the microphone must not be too big. Then a simple clip microphone can be used instead as it

does not influence the sound field. The microphone should have a flat frequency response.

Place the microphone on a stand positioned at the listening seat. Leave the microphone pointing upwards in order to avoid sound pressure build-up in front of the diaphragm and to provide equal conditions to monitors in all directions.

Connect the microphone to a mixing desk or a recording machine that has a meter built in.

Play back a track containing pink noise on the CD you got with the monitors. (or use one of the other tracks as instructed to during setup and calibration.

Adjust the gain in the microphone channel until the meter deflection reaches a point 10 dB below full scale. This is now your reference for your measurements. Be sure that you have marks on the scale that makes it possible to read steps of 1 or 2 dB on either side of the reference deflection. If 10 dB below full scale is not an adequate point on your meter you may choose another one, just be sure to have a reading on a adequate resolution.

If you use this microphone setup as described, it can be used for the level comparison between the individual monitors.

Absolute sound pressure levels can be measured if you:

a)are using a well calibrated microphone channel

b)know the sensitivity of the microphone.

43

Image 45
Contents Page Page Voltage Line plug according to standard Important Safety InstructionsPage Table of Contents Quick Setup Reference Quick Setup Reference Main Display Operational OverviewStereo Setup SetupsStereo Setup with mono Subs Stereo Setup with stereo SubsAnalog Setup Digital SetupThis illustration shows how to connect a 5.1 digital setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Analog setup This illustration shows how to connect a 5.3 Digital setupDig/6 Master This illustration shows how to connect a 6.1 Analog setupOther Chained Setups Stereo Setup With Chains on L & RAnalog/Digital setup Analog connectionsDigital 192 kHz Digital Setup This Manual IntroductionBreak Product ConceptCommon Features Remote ControlMaster Unit Slave & Sub UnitsMaster Unit Analog I/O Rear Panel Description MasterSlave/Sub Optional Digital I/O cardOverload Indication AIR DisplayEnter key Cursor UP/DOWN keys Overload Indication LEDParameter Description Press Enter to access the Select ModeBasic operation in all menus Main DisplaySetup Setup MenuSet Monitor Task External ClockLFE channel note RecallStore Overview Placing the MonitorsClose to wall / Wall On the bridge / ConsoleOther situations Phase checking Checking the placementChecking by ear when listening to the signals In phase EvaluationNext EqualizingInterchannel calibration Calibrating Main Monitors CurvesAcoustic level calibration CurvePlacing the Subwoofer Evaluation Low frequency sweepsTo Calibrate Checking summing phase cancellationControlling standing waves Checking the CrosspointPhase Introduction PhaseLFE Gain PolarityAcoustics Good acousticsReverberation time Sabines formula Diffusers AbsorbersMembrane absorbers Absorbtion or diffusion ? Resonance absorbersStanding Waves Background Info AcousticsAxial Tangential Radial Room modesHow does the standing waves influence the sound field? How to prohibit standing wavesAcoustics Background Info Comb Filtering Dip frequencies Or +Rear wall cancellation Subwoofer Subwoofer Background InfoLFE Channel Subwoofer & LFE Channel Background InfoCross-overs Low Pass LFE GainDelaying Monitors LINE-UP & Calibration Acoustic summation of audio signalsCinema setup How to measure the sound pressure? LINE-UP & Calibration Background InfoCalibration of 5.1 in an ITU-775 arrangement Remote Control Features AIR RemoteIntroduction Volume potentiometer Preset 1/3 and 2/4 keysREF Level 1-3 keys Shift keyNavigating AIR Soft AIR SoftTools MainNetwork Preset ListSystem Setup Chained monitors Calibrate AIR-BaseMiscellaneous Reset ProceduresGlobal Parameters Local ParametersTC Link Standard Cat-5 cables CablesAES/EBU Standard cables Serial to Cat-5 cableAIR 20 & AIR 25 Master and Slave AIR 6 & AIR 15 Master and SlaveAIR Base AIR-Base-1 & AIR-Base-2Room & Distance General for all ProductsAIR Remote specs Error messages etc Delay in System & Error Messages ETCCertificate of Conformity Certificate Of ConformityAIR AIR-Base # Name Preset List